Calibration of pulse contour continuous cardiac output analysis

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous cardiac output measurement: pulse contour analysis vs thermodilution technique in cardiac surgical patients.

We have analysed the clinical agreement between two methods of continuous cardiac output measurement pulse contour analysis (PCCO) and a continuous thermodilution technique (CCO), were both compared with the intermittent bolus thermodilution technique (BCO). Measurements were performed in 26 cardiac surgical patients (groups 1 and 2, 13 patients each, with an ejection fraction > 45% and < 45%, ...

متن کامل

Continuous cardiac output monitoring with pulse contour analysis: a comparison with lithium indicator dilution cardiac output measurement.

OBJECTIVE Pulse contour analysis can be used to provide beat-to-beat cardiac output (CO) measurement. The current study sought to evaluate this technique by comparing its results with lithium dilution CO (LiCO) measurements. DESIGN Prospective, observational study. SETTING Surgical intensive care unit. PATIENTS Twenty-two patients after cardiac or major noncardiac surgery. MEASUREMENTS ...

متن کامل

Effect of norepinephrine dosage and calibration frequency on accuracy of pulse contour-derived cardiac output

INTRODUCTION Continuous cardiac output monitoring is used for early detection of hemodynamic instability and guidance of therapy in critically ill patients. Recently, the accuracy of pulse contour-derived cardiac output (PCCO) has been questioned in different clinical situations. In this study, we examined agreement between PCCO and transcardiopulmonary thermodilution cardiac output (COTCP) in ...

متن کامل

Lack of agreement between esophageal doppler cardiac output measurements and continuous pulse contour analysis during off-pump cardiac surgery

Objective: Transesophageal echo-Doppler cardiac output as well as arterial pulse contour analyses cardiac output are increasingly used for cardiac output monitoring. No data are available whether both techniques may be used interchangeably in patients undergoing cardiac surgery. Design: Prospective, observational study Setting: Operating rooms of a university affiliated hospital. Patients: 30 p...

متن کامل

Sequential Organ Failure Assessment predicts outcomes of pulse indicator contour continuous cardiac output-directed goal therapy

According to the new sepsis definitions, septic shock is defined as a subset of sepsis in which the underlying circulatory and cellular/metabolic abnormalities are profound enough to substantially increase mortality. We evaluated the predictive efficacy of the Sequential Organ Failure Assessment (SOFA) score in critically ill patients with septic shock undergoing pulse indicator contour continu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Critical Care

سال: 2009

ISSN: 1364-8535

DOI: 10.1186/cc7370