Calibration of scintillation detectors for MeV charged fusion products
نویسندگان
چکیده
منابع مشابه
New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras
Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...
متن کاملnew approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras
introduction:surgeosight is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (sln) imaging in the operation room. like conventional gamma cameras it is necessary to calibrate surgeosight for linearity distortion, ener...
متن کاملScintillation detectors for x-rays
Recent research in the field of phosphor and scintillator materials and related detectors is reviewed. After a historical introduction the fundamental issues are explained regarding the interaction of x-ray radiation with a solid state. Crucial parameters and characteristics important for the performance of these materials in applications, including the employed measurement methods, are describ...
متن کاملPixel Detectors for Charged Particles
Pixel Detectors, as the current technology of choice for the innermost vertex detection, have reached a stage at which large detectors have been built for the LHC experiments and a new era of developments, both for hybrid and for monolithic or semi-monolithic pixel detectors is in full swing. This is largely driven by the requirements of the upgrade programme for the superLHC and by other colli...
متن کاملN ov 1 99 5 Calibration of Plastic Phoswich Detectors for Charged Particle Detection
The response of an array of plastic phoswich detectors to ions of 1 ≤ Z ≤ 18 has been measured from E/A=12 to 72 MeV. The detector response has been parameterized by a three parameter fit which includes both quenching and high energy delta-ray effects. The fits have a mean variation of ≤ 4% with respect to the data.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Review of Scientific Instruments
سال: 1992
ISSN: 0034-6748,1089-7623
DOI: 10.1063/1.1143714