Calibration of time domain network analyzers
نویسندگان
چکیده
منابع مشابه
Improved Rf Hardware and Calibration Methods for Network Analyzers
The degree to which measurement accuracy in a vector network analyzer can be improved through error correction is dependent on a number of factors. Modern error correction methods have improved the system accuracy and simplified the calibration procedure. Methods are in place to determine the accuracy of error corrected measurements. And the quality of the calibration standards is key to system...
متن کاملAnalysis and reduction of the distortions induced by time-domain filtering techniques in network analyzers
The removal of isolation errors plays an essential role in the calibration process of radar scattering measurements. One of the most common techniques used for that purpose is timedomain filtering, also known as gating. In spite of the importance of gating techniques, however, little can be found about them in the open literature. This paper analyzes these techniques and provides the concepts r...
متن کاملSources of noise in Brillouin optical time-domain analyzers
This paper presents a thorough study of the different sources of noise affecting Brillouin optical time-domain analyzers (BOTDA), providing a deep insight into the understanding of the fundamental limitations of this kind of sensors. Analytical and experimental results indicate that the noise source ultimately fixing the sensor performance depends basically on the fiber length and the input pum...
متن کاملNew theoretical analysis of the LRRM calibration technique for vector network analyzers
In this paper, a new theoretical analysis of the fourstandards line-reflect-reflect-match (LRRM) vector network-analyzer (VNA) calibration technique is presented. As a result, it is shown that the reference-impedance (to which the LRRM calibration is referred) cannot generally be defined whenever nonideal standards are used. Based on this consideration, a new algorithm to determine the on-wafer...
متن کاملCalibration of Infra-red CO(2) Gas Analyzers.
Precision gas mixing pumps produce CO(2) gas mixtures for the calibration of infra-red CO(2) gas analyzers equivalent in accuracy to the standard CO(2) gas mixtures (+/- 1%) supplied by the National Bureau of Standards, Washington, D. C.The calibration of infra-red gas analyzers by the pressure difference method and by concentration differences did not agree. A factor of 0.709 was necessary to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Instrumentation and Measurement
سال: 1993
ISSN: 0018-9456
DOI: 10.1109/19.278540