Posterior approach and uncemented stems increases the risk of reoperation after hemiarthroplasties in elderly hip fracture patients
BACKGROUND Hemiarthroplasties are performed in great numbers worldwide but are seldom registered on a national basis. Our aim was to identify risk factors for reoperation after fracture-related hemiarthroplasty in Norway and Sweden. MATERIAL AND METHODS A common dataset was created based on the Norwegian Hip Fracture Register and the Swedish Hip Arthroplasty Register. 33,205 hip fractures in ...
متن کاملPeriprosthetic bone loss after insertion of an uncemented, customized femoral stem and an uncemented anatomical stem
BACKGROUND AND PURPOSE Customized femoral stems are designed to have a perfect fit and fill in the femur in order to achieve physiological load transfer and minimize stress shielding. Dual-energy X-ray absorptiometry (DXA) is regarded as an accurate method for detection of small alterations in bone mineral density (BMD) around hip prostheses. We present medium-term DXA results from a randomized...
متن کاملMore re-operations after uncemented than cemented hemiarthroplasty used in the treatment of displaced fractures of the femoral neck: an observational study of 11,116 hemiarthroplasties from a national register.
Using data from the Norwegian Hip Fracture Register, 8639 cemented and 2477 uncemented primary hemiarthroplasties for displaced fractures of the femoral neck in patients aged > 70 years were included in a prospective observational study. A total of 218 re-operations were performed after cemented and 128 after uncemented procedures. Survival of the hemiarthroplasties was calculated using the Kap...
متن کاملUncemented fully hydroxyapatite-coated hip stem for intracapsular femoral neck fractures in osteoporotic elderly patients: a multicenter study
There is still debate over the limits of age and bone stock quality of patients on whom to use an un-cemented straight stem coated with hydroxyapatite (HA). We studied a group of 244 patients with a displaced intracapsular fracture of the femoral neck who underwent cementless hemiarthroplasty or total hip arthroplasty. 143 patients were reviewed at the two-year follow up. A fully HA-coated stem...
متن کاملEffects of hydroxyapatite coating on survival of an uncemented femoral stem
BACKGROUND AND PURPOSE Hydroxyapatite (HA) is widely used as a coating for uncemented total hip arthroplasty components. This has been suggested to improve implant ingrowth and long-term stability. However, the evidence behind the use of HA coating on femoral stems is ambiguous. We investigated survival of an uncemented, tapered titanium femoral stem that was available either with or without HA...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Injury Extra
سال: 2012
ISSN: 1572-3461
DOI: 10.1016/j.injury.2012.07.296