Cantilever-based microring lasers embedded in a deformable substrate for local strain gauges
نویسندگان
چکیده
منابع مشابه
Embedded Strain Gauges for Condition Monitoring of Silicone Gaskets
A miniaturized strain gauge with a thickness of 5 µm is molded into a silicone O-ring. This is a first step toward embedding sensors in gaskets for structural health monitoring. The signal of the integrated sensor exhibits a linear correlation with the contact pressure of the O-ring. This affords the opportunity to monitor the gasket condition during installation. Thus, damages caused by faulty...
متن کاملPT-symmetric microring lasers
Mohammad-Ali Miri,* Hossein Hodaei, Matthias Heinrich, Mercedeh Khajavikhan, Demetrios N. Christodoulides CREOL, College of Optics and Photonics, University of Central Florida, Orlando, Florida 32816-2700, USA [email protected] Abstract: We show that a multimode laser cavity when accompanied by an identical but lossy partner can lase at a single longitudinal mode. Our experimental results de...
متن کاملPassive microring-resonator-coupled lasers
In this letter, a passive microring-resonator-coupled semiconductor laser structure is proposed. The weakly coupled high-Q microring resonator provides a strong mode-selection filter and could considerably extend the effective cavity length of a conventional Fabry–Perot laser. The side-mode suppression ratio, the linewidth and the frequency chirp of this laser are dramatically improved comparin...
متن کاملParity-time-symmetric microring lasers.
The ability to control the modes oscillating within a laser resonator is of fundamental importance. In general, the presence of competing modes can be detrimental to beam quality and spectral purity, thus leading to spatial as well as temporal fluctuations in the emitted radiation. We show that by harnessing notions from parity-time (PT) symmetry, stable single-longitudinal mode operation can b...
متن کاملComparisons between Membrane, Bridge and Cantilever Miniaturized Resistive Vacuum Gauges
Using bulk micromachining, meander-shaped resistor elements consisting of 20 nm Cr and 200 nm Au were fabricated on 1 μm thick silicon nitride membranes, bridges, and cantilevers. The resistance change as a function of pressure depends strongly on the thermal resistance of the two metal lines connecting the heated resistor to the silicon bulk (cold junction) and on the thermal resistance of the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: AIP Advances
سال: 2018
ISSN: 2158-3226
DOI: 10.1063/1.5033365