Cathode readout with stripped resistive drift tubes
نویسندگان
چکیده
منابع مشابه
Resistive drift-wave turbulence
Two-dimensional resistive drift-wave turbulence is studied by high-resolution numerical simulations in the Iimit of small viscosity. Density and potential fluctuations are cross-coupled by resistive dissipation, proportional to the adiabaticity parameter, F, which determines the character of the system: adiabatic (ml) or hydrodynamic (Z% 1). Various cases are computed for 0. I ~%<5. Energy spec...
متن کاملA Study of Mwpc with Chevron Cathode Pad Readout
An investigation of MWPCs with interpolating chevron shaped cathode pad readout has been carried out as part of the R&D for the particle tracking system of the PHENIX detector at RHIC. Two prototype chambers were designed and constructed. Their response to minimum ionizing particles was tested with secondary beams from the Alternating Gradient Synchrotron (AGS) at Brookhaven National Laboratory...
متن کاملRate effects in a proportional counter with resistive cathode
In this work, the rate effects associated with the gain of detectors with resistive electrodes are considered. To study these effects it was decided to use the classical proportional counter geometry, with a cylindrical glass tube as the cathode, rather than parallel plate devices. Indeed, the generality of the information obtained is not affected and the cylindrical proportional counter geomet...
متن کاملImproved Circuits with Capacitive Feedback for Readout Resistive Sensor Arrays
One of the most suitable ways of distributing a resistive sensor array for reading is an array with M rows and N columns. This allows reduced wiring and a certain degree of parallelism in the implementation, although it also introduces crosstalk effects. Several types of circuits can carry out the analogue-digital conversion of this type of sensors. This article focuses on the use of operationa...
متن کاملOptimization of drift gases for accuracy in pressurized drift tubes
Modern detectors such as ATLAS use pressurized drift tubes to minimize diffusion and achieve high coordinate accuracy. However, the coordinate accuracy depends on the exact knowledge of converting measured times into coordinates. Linear spacetime relationships are best for reconstruction, but difficult to achieve in the E ∝ 1 r field. Previous mixtures, which contained methane or other organic ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 1995
ISSN: 0168-9002
DOI: 10.1016/0168-9002(95)00658-3