Characteristics in Water Phantom of Epithermal Neutron Beam Produced by Double Layer Beam Shaping Assembly
نویسندگان
چکیده
منابع مشابه
Epithermal Neutron Beam Generator Design for Bnct
BNCT is a radiotherapy modality based on the neutron capture and fission reactions that occur when boron-10 is irradiated by thermal neutrons. This reaction generates alpha and lithium that produce high density of ionizations in close to the reaction site. The concept provides high absorbed doses into the cancerous cells preserving the adjacent healthy tissues. Nowadays, the available neutron s...
متن کاملFir 1 Epithermal Neutron Beam Model and Dose Calculation for Treatment Planning in Neutron Capture Therapy
The epithermal neutron beam model of the Finnish boron neutron capture therapy (BNCT) facility (FiR 1) was created using the two-dimensional (2D) discrete ordinates transport (DORT) code. The final design of the beam was achieved using the DORT model: the optimal thickness of the neutron moderator and the length and the thickness of the bismuth collimator of the beam were calculated. The final ...
متن کاملOptimization study for BNCT facility based on a DT neutron generator
Background: A Boron Neutron Capture Therapy (BNCT) facility, based on a DT neutron generator, with the final goal to find out a potential, alternative, solution to existing BNCT treatment facilities which are based on nuclear reactors is examined. Materials and Methods: With the aim of the MCNP4B Monte Carlo code different beam-shaping assembly (BSA) configurations were considered. Lead was sel...
متن کاملFinnish dosimetric practice for epithermal neutron beam dosimetry in boron neutron capture therapy
Boron neutron capture therapy (BNCT) is a form of chemically targeted radiotherapy that utilises the high neutron capture cross-section of boron-10 isotope to achieve a preferential dose increase in the tumour. The BNCT dosimetry poses a special challenge as the radiation dose absorbed by the irradiated tissues consists of several dose components with different relative biological effectiveness...
متن کاملSimulation of the BNCT of Brain Tumors Using MCNP Code: Beam Designing and Dose Evaluation
Introduction BNCT is an effective method to destroy brain tumoral cells while sparing the healthy tissues. The recommended flux for epithermal neutrons is 109 n/cm2s, which has the most effectiveness on deep-seated tumors. In this paper, it is indicated that using D-T neutron source and optimizing of Beam Shaping Assembly (BSA) leads to treating brain tumors in a reasonable time where all IAEA ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: ASEAN Journal on Science and Technology for Development
سال: 2019
ISSN: 2224-9028,0217-5460
DOI: 10.29037/ajstd.519