Characteristics of Indicators for Insulation Deterioration in 26 kV Generator Stator Windings
نویسندگان
چکیده
منابع مشابه
Study of Aging Characteristics of Generator Stator Insulation Based on Temperature Spectrum of Dielectric Dissipation Factor
In this paper, accelerated multi-factor aging tests in laboratory have been conducted on the stator ham of a large generator. During the period of aging, the temperature spectra of dielectric dissipation factor tan 6 of stator insulation were employed to investigate aging characteristics of insulation materials. Test results showed that the peak temperature T,,, of the tan 6 -T curve under 0.2U...
متن کاملA novel protection scheme for synchronous generator stator windings based on SVM
This paper proposes a novel scheme for detecting and classifying faults in stator windings of a synchronous generator (SG). The proposed scheme employs a new method for fault detection and classification based on Support Vector Machine (SVM). Two SVM classifiers are proposed. SVM1 is used to identify the fault occurrence in the system and SVM2 is used to determine whether the fault, if any, is ...
متن کاملPartial discharge database: its benefits and limitations on assessment of stator insulation deterioration
PD test data on various generators and motors has been collected over the last 15 years using on-line partial discharge analyzers. A large PD test database has been established. The database provides an overall view of PD activity on rotating machines. Statistical analysis of the database provides a study of PD distribution with variations of a number of the parameters. This paper presents stat...
متن کاملImprovement of Stator Slot Structure based on Insulation Stresses Analysis in HV Generator
High voltage generators are being subject to higher voltage rating and are being designed to operate in harsh conditions. Stator windings are the main component of generators in which Electrical, magnetical and thermal stresses remain major failures for insulation degradation accelerated aging. A large number of generators failed due to stator winding problems, mainly insulation deterioration. ...
متن کاملDual Stator Induction Generator For Rural Electrification
The paper presents an electromechanical auto synchronized wind energy conversion system (WECS) for larger penetration of renewable energy sources (RES) in the rural electrification systems. The architecture of the WECS uses two stator windings at power frequency which provides harvesting of power to flow from WECS to load and to grid side when the generated power is in access. Asymmetrical six ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: American Journal of Electrical Power and Energy Systems
سال: 2019
ISSN: 2326-912X
DOI: 10.11648/j.epes.20190806.11