Characterization of a charge-coupled device array for Bragg spectroscopy

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical sensor interrogation with a blazed fiber Bragg grating and a charge-coupled device linear array.

We present what is to our knowledge the first comprehensive investigation of the use of blazed fiber Bragg gratings (BFBGs) to interrogate wavelength division multiplexed (WDM) in-fiber optical sensor arrays. We show that the light outcoupled from the core of these BFBGs is radiated with sufficient optical power that it may be detected with a low-cost charge-coupled device (CCD) array. We prese...

متن کامل

Charge-coupled device area x-ray detectors

Charge-coupled device ~CCD! area x-ray detector technology is reviewed. CCD detectors consist of a serial chain of signal components, such as phosphors, fiber optics or lenses, image intensifiers and the CCD which serve to convert the x-ray energy to light or electron-hole pairs and to record the spatially resolved image. The various combinations of components that have been used to make CCD de...

متن کامل

Hysteresis Characterization Using Charge-Feedback Control for a LIPCA Device

In this paper, we study the no-load behavior of a lightweight piezo-composite curved actuator (LIPCA) subjected to voltage and charge control. First, we examine the effect of hysteresis and creep when the actuator is voltage controlled at a slow scan speed. The experimental results show that creep increases the displacement hysteresis by over 25% when scanning at 1/60 Hz. Afterwards, we discuss...

متن کامل

Spectroscopy of superconducting charge qubits coupled by a Josephson inductance

T. Yamamoto,1,2 M. Watanabe,2 J. Q. You,2,3 Yu. A. Pashkin,1,2,* O. Astafiev,1,2 Y. Nakamura,1,2 F. Nori,2,4 and J. S. Tsai1,2 1NEC Nano Electronics Research Laboratories, Tsukuba, Ibaraki 305-8501, Japan 2Frontier Research System, The Institute of Physical and Chemical Research (RIKEN), Wako-shi, Saitama 351-0198, Japan 3Department of Physics and Surface Physics Laboratory (National Key Labora...

متن کامل

Calibration procedures for charge-coupled device x-ray detectors

Calibration procedures are described for use with electronic x-ray detectors, with an emphasis on detectors based on fiber-optically coupled charge-coupled devices. Methods are detailed for removing spurious events, pixel pedestals, dark-current, spatial distortion, and intensity response variations for both small-angle and wide-angle applications. The accuracy of the calibration procedures is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Review of Scientific Instruments

سال: 2006

ISSN: 0034-6748,1089-7623

DOI: 10.1063/1.2194485