Chronic haemolysis after Lillehei-Kaster valve replacement. Comparison with the findings after Bjork-shiley and Starr-Edwards mitral valve replacement.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Haemolysis after mitral valve replacement with the Björk-Shiley and the Lillehei-Kaster disc valve prosthesis.

The present study reports on the incidence and degree of intravascular haemolysis in 33 patients with Björk-Shiley tilting disc prosthesis and in 34 patients with Lillehei-Kaster pivoting disc valve prosthesis in the mitral position examined 12 to 24 months after the operation. Serum haptoglobin, serum lactate dehydrogenase, serum bilirubin, and haemoglobin estimations were performed. Significa...

متن کامل

Intravascular haemolysis after valve replacement: comparative study between Starr-Edwards (ball valve) and Björk-Shiley (disc valve) prosthesis.

Seventy-four patients with single prosthetic valves (Björk-Shiley or Starr-Edwards) in the mitral or aortic position and 18 controls with rheumatic valvar heart disease were investigated for evidence of intravascular haemolysis. Serum lactate dehydrogenase (LDH) was used as the most sensitive indicator of haemolysis. Raised concentrations were found in a third of 39 patients with Björk-Shiley p...

متن کامل

Right sided heart evaluation after successful mitral valve replacement.

Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...

متن کامل

Thromboembolism after Starr valve replacement.

One hundred and six patients who left hospital after Starr-Edwards ball valve replacements have beenfollowedfor a period of 6 months tO 4 years. All patients were maintained on oral anticoagulant therapy so that a prothrombin ratio of approximately I 7:I was attained. Four patients suffered minor nose bleeds. During the period offollow-up there have been 4 patients who have suffered embolic phe...

متن کامل

Prophylactic reoperation after mitral valve replacement with the Starr-Edwards ball valve: a report of four cases.

PURPOSE The Starr-Edwards ball valve was first applied clinically in 1960. In our hospital, this valve has been used since 1963, and some patients have been followed up for 30 years or more. Based on our experience, therapeutic strategies included revalve replacement as a preventive procedure in the absence of valve-related complications. In this study, we investigated whether prophylactic reop...

متن کامل