Circulating Current Analysis and Suppression for Module Grid-Connected Inverters Under Unbalanced Conditions
نویسندگان
چکیده
منابع مشابه
An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions. It is challenging to suppress the harmonic content in the output current below a pre-set value in...
متن کاملCurrent Harmonics from Single-Phase Grid-Connected Inverters – Examination and Suppression
Environmental conditions and operational modes may significantly impact the distortion level of the injected current from single-phase grid-connected inverter systems, such as photovoltaic (PV) inverters, which may operate in cloudy days with a maximum power point tracking, in a non-unity power factor, or in the low voltage ride through mode with reactive current injection. In this paper, the m...
متن کاملPll for Single Phase Grid Connected Inverters
In grid connected applications the synchronization of output signals of the converters to be connected with grid parameters frequency and phase is of great importance. Different methods based on Fourier transforms, zero-crossing detection, Kalman filters, phase-locked loops (PLL) and others are used for this synchronization. This paper presents a new PLL for synchronization of the output curren...
متن کاملResonant Characteristics Analysis and Suppression Strategy of Multiple Parallel Grid-connected Inverters with LCL Filter
The multiple parallel inverters have more than one resonant frequency influenced by many factors, which tends to result in stability and power quality problems. This paper develops the multiple input multiple output model of the grid-connected inverters system using the closed-loop transfer function. The influence factors of resonant characteristics are analyzed with the developed model. The an...
متن کاملSliding Mode Control of a Grid-Connected Distributed Generation Unit under Unbalanced Voltage Conditions
The increasing presence of inverter-based distributed generation (DG) units in distribution networks (DNs) requires control methods that achieve high performance not only during normal operating conditions, but also under unbalanced conditions. With a high probability, a type of voltage unbalance in DNs is unequal three-phase voltage magnitudes at the fundamental system frequency. This can occu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Access
سال: 2018
ISSN: 2169-3536
DOI: 10.1109/access.2018.2877955