Clinical Evaluation of a Two-step Etch&Rinse and a Two-step Self-etch Adhesive System in Class II Restorations: Two-year Results
نویسندگان
چکیده
منابع مشابه
Microleakage assessment of one- and two-step self-etch adhesive systems with the low shrinkage composites
BACKGROUND AND AIM: Different studies evaluating one-step self-etch (SE) adhesive systems show contradictory findings, so the aim of this study was to compare the microleakage of one-step SE adhesive systems and CLEARFIL SE BOND (that serves as the “gold-standard” SE adhesive) with low shrinkage composites. METHODS: In this in vitro study, Class V cavities with the occlusal margin in enamel and...
متن کاملThree-year clinical evaluation of posterior composite restorations placed with a single-step self-etch adhesive.
In this clinical study, we evaluated the 3-year clinical performance of a resin composite containing a surface-prereacted glass ionomer (S-PRG) filler (Beautifil II; Shofu Inc., Kyoto, Japan) placed with a single-step self-etch adhesive (BeautiBond; Shofu Inc.) in posterior restorations. Using modified US Public Health Service criteria, two experienced investigators performed clinical evaluatio...
متن کاملSodium fluoride addition to a two-step etch-and-rinse adhesive system: effect on dentin microtensile bond strength and durability
Introduction: Studies have suggested that sodium fluoride (NaF) has an inhibitory effect on the activity of endogenous matrix metalloproteinase enzymes. This study assessed the effect of a fluoride-containing adhesive on microtensile bond strength (µTBS) over time. Material & Methods: In this experimental study, 36 extracted third molars were used to evaluate the µTBS of...
متن کاملEffect of water storage on microtensile bond strength of a two-step self-etch adhesive and a two-step etch-and-rinse adhesive.
This study evaluated the effect of 24 h (1d) and one-year (1yr) water storage on the microtensile dentin bond strength of a two-step total-etch and a two-step self-etch adhesive system. Ten extracted human third molars were sectioned perpendicularly to their long axis to expose flat occlusal dentin surfaces. Teeth were divided into two groups (n=5) according to the adhesive used: a two-step etc...
متن کاملTwo-year clinical evaluation of one-step self-etch systems in non-carious cervical lesions.
OBJECTIVES This randomized controlled clinical trial evaluated the 2-year clinical performance of S3 Bond (S3) and G-Bond (GB) in 108 non-carious cervical lesions. METHODS Twenty-three patients, 12 male and 11 female (mean age: 61.8 years, range: 30-79 years) regularly visiting the Nagasaki University Hospital of Medicine and Dentistry, participated in the study. Each patient received both ma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Operative Dentistry
سال: 2009
ISSN: 1559-2863,0361-7734
DOI: 10.2341/08-114-c