Clinical Evaluation of the Automated COBAS AMPLICOR HCV MONITOR Test Version 2.0 for Quantifying Serum Hepatitis C Virus RNA and Comparison to the Quantiplex HCV Version 2.0 Test

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical evaluation of the automated COBAS AMPLICOR HCV MONITOR test version 2.0 for quantifying serum hepatitis C virus RNA and comparison to the quantiplex HCV version 2.0 test.

A second-generation hepatitis C virus (HCV) quantitative assay (COBAS AMPLICOR HCV MONITOR Test, version 2.0; COBAS HCM-2) has been developed, with the intention of achieving equivalent quantification of all HCV genotypes and improving assay performance. To evaluate the clinical performance of COBAS HCM-2 and its utility in predicting the response to alpha interferon treatment, sera from 215 ch...

متن کامل

Clinical application of the Quantiplex HCV RNA 2.0 and Amplicor HCV Monitor assays for quantifying serum hepatitis C virus RNA.

AIM To compare the performance characteristics and clinical application of two different technologies for quantifying serum hepatitis C virus (HCV) RNA levels. METHODS HCV RNA was quantified by Amplicor HCV Monitor assay (Amplicor) and Quantiplex HCV RNA 2.0 assay (bDNA-2) in 119 sera from 107 HCV infected patients. RESULTS Both assays had similar sensitivity (79.4% for Amplicor; 86.0% for ...

متن کامل

Assessment of viral loads in patients with chronic hepatitis C with AMPLICOR HCV MONITOR version 1.0, COBAS HCV MONITOR version 2.0, and QUANTIPLEX HCV RNA version 2.0 assays.

The correlation between response to antiviral therapy and pretreatment viral load in patients with chronic hepatitis C has prompted the development of quantitative assays to measure viral load. The aim of our study was to assess the clinical relevance of the newly developed semiautomated PCR system COBAS HCV MONITOR version 2.0 in comparison with (i) the AMPLICOR HCV MONITOR version 1.0 assay, ...

متن کامل

Papers Clinical application of the Quantiplex HCV RNA 2.0 and Amplicor HCV Monitor assays for quantifying serum hepatitis C virus RNA

Aim—To compare the performance characteristics and clinical application of two diVerent technologies for quantifying serum hepatitis C virus (HCV) RNA levels. Methods—HCV RNA was quantified by Amplicor HCV Monitor assay (Amplicor) and Quantiplex HCV RNA 2.0 assay (bDNA-2) in 119 sera from 107 HCV infected patients. Results—Both assays had similar sensitivity (79.4% for Amplicor; 86.0% for bDNA2...

متن کامل

Overestimation of the hepatitis C virus RNA content of reference preparations by the AMPLICOR HCV monitor test, version 2.0.

An evaluation of the AMPLICOR hepatitis C virus (HCV) monitor test, version 2.0 (Roche Diagnostics), was carried out to investigate whether this test overestimates the HCV RNA content of reference preparations. Satisfactory accuracy was observed when the World Health Organization HCV international standard was included in the assay and a modified formula was used to calculate the viral content.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Clinical Microbiology

سال: 2000

ISSN: 0095-1137,1098-660X

DOI: 10.1128/jcm.38.8.2933-2939.2000