Clinical outcome and physical activity measured with StepWatch 3™ Activity Monitor after minimally invasive total hip arthroplasty
نویسندگان
چکیده
منابع مشابه
Minimally Invasive Total Hip Arthroplasty
Total hip arthroplasty (THA) is one of the most reliable procedures that can provide shortterm high clinical success rates and long-term durable outcome. The surgery has been developed for more than 40 years and most of the clinical practices are standardized for the patient care. In the past, THA had been done by making a wound about 25 cm in length. Many surgeons believed that big wounds shou...
متن کاملPhysical activity of elderly patients after total hip arthroplasty.
BACKGROUND Total hip arthroplasty (THA) is the most common method of treatment of severe hip osteoarthritis. There is little data concerning the physical activity of total hip arthroplasty patients in Poland and investigations to explore this area are useful. The aim of the study was to describe the post-operative physical activity of total hip arthroplasty patients. MATERIAL AND METHODS A to...
متن کاملMinimally invasive approaches in total hip arthroplasty.
The success of operative treatment depends on a quick recovery of limb function. Every injury to a muscle or its attachment is associated with decreased muscle strength and disturbed proprioception, which impedes functional recovery. Minimally Invasive Surgery (MIS) is defined as a surgical technique performed through a short skin incision to avoid injury to muscles and tendons. The advantages ...
متن کاملPhysical Activity After Total Joint Arthroplasty
CONTEXT Total joint arthroplasty (TJA) is a common surgical option to treat painful degenerative joint disease. However, there is currently no consensus on the appropriate intensity of physical activity after TJA or how physical activity level affects the rate of revision surgery. MATERIALS AND METHODS A systematic review of the literature regarding physical or athletic activity after TJA was...
متن کاملMinimally invasive hip resurfacing compared to minimally invasive total hip arthroplasty.
BACKGROUND Since its March 2006 FDA approval in the United States, Birmingham hip resurfacing (BHR) has been a popular alternative to hip arthroplasty for the younger patient population. Data to date has shown a trend toward low incidence of dislocation and good survivorship. METHODS 128 patients operated on by a single surgeon from July 2006 to December 2008 were reviewed for complications, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Orthopaedic Surgery and Research
سال: 2018
ISSN: 1749-799X
DOI: 10.1186/s13018-018-0775-4