Clinically Significant Organ-at-risk Dose Reductions Are Achieved with IMRT Plan Optimization to Clinical Target Volume (CTV) with Setup Uncertainty Analysis
نویسندگان
چکیده
منابع مشابه
Clinical implementation of dose-volume histogram predictions for organs-at-risk in IMRT planning
True quality control (QC) of the planning process requires quantitative assessments of treatment plan quality itself, and QC in IMRT has been stymied by intra-patient anatomical variability and inherently complex three-dimensional dose distributions. In this work we describe the development of an automated system to reduce clinical IMRT planning variability and improve plan quality using mathem...
متن کاملUsefulness of 4D-CT for radiation treatment planning of gastric MZBCL/MALT.
It is well known that significant variations in stomach size, shape, and respiratory motion lead to uncertainties in target localization during treatment for gastric lymphoma. In this study, the usefulness of 4D-CT for radiation planning of gastric MZBCL/MALT was evaluated. Treatment planning using 4DCT (plan A) and conventional planning with a uniform margin (plan B) were compared using dose v...
متن کاملComparison of dosimetric and radiobiological effects of various IMRT techniques regarding to joint volume between target tissue and organs at risk in prostate cancer patients
Background: Intensity-modulated radiotherapy (IMRT) is one of the most usable methods in prostate radiotherapy that is used with different techniques. The aim of this study was to evaluate and compare the dosimetric and radiobiological effects of prostate IMRT techniques regarding to joint volume between the target tissue and organs at risk as a patients anatomical parameter. Methods: This res...
متن کاملRobust plan optimization using edge-enhanced intensity for intrafraction organ deformation in prostate intensity-modulated radiation therapy
This study evaluated a method for prostate intensity-modulated radiation therapy (IMRT) based on edge-enhanced (EE) intensity in the presence of intrafraction organ deformation using the data of 37 patients treated with step-and-shoot IMRT. On the assumption that the patient setup error was already accounted for by image guidance, only organ deformation over the treatment course was considered....
متن کاملMatching target dose to target organ
In vitro assays have become a mainstay of modern approaches to toxicology with the promise of replacing or reducing the number of in vivo tests required to establish benchmark doses, as well as increasing mechanistic understanding. However, matching target dose to target organ is an often overlooked aspect of in vitro assays, and the calibration of in vitro exposure against in vivo benchmark do...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Radiation Oncology*Biology*Physics
سال: 2018
ISSN: 0360-3016
DOI: 10.1016/j.ijrobp.2018.07.1486