CO2Capture Process using Aqueous Monoethanolamine (MEA): Reduction of Solvent Regeneration Energy by Flue gas Splitting
نویسندگان
چکیده
منابع مشابه
Solvent Formulation for CO2 Separation from Flue Gas Streams
CO2 separation using reactive solvents is considered to be a technically viable option for capturing of CO2 from flue gas streams. However, the cost of CO2 capture using conventional solvents such as aqueous solutions of monoethanolamine (MEA) is prohibitively high. Nearly half of the total cost is due to operational costs, of which about 70 to 80% can be contributed to the cost of regeneration...
متن کاملA Numerical Study on Using Air Cooler Heat Exchanger for Low Grade Energy Recovery from Exhaust Flue Gas in Natural Gas Pressure Reduction Stations
Heat EXchangers (HEX) that are used in City Gate Station (CGS) systems are modeled numerically to recover the exhaust waste heat. It was tried to find the best viscous model to obtain results in accordance with experimental results and to change the heat exchanger design. This HEX is used for recovering heat from exhaust flue gas with a mixture of 40% water and 60% ethylene glycol as the coolin...
متن کاملA means to an interface: investigating monoethanolamine behavior at an aqueous surface.
The use of amine scrubbers to trap carbon dioxide from flue gas streams is one of the most promising avenues for atmospheric carbon dioxide reduction. However, modifications are necessary to efficiently scale these scrubbers for use in fossil fuel plants. Current advances in tailoring amines for CO2 capture involve improvements of bulk kinetic and thermodynamic parameters, with little considera...
متن کاملhazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures
شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...
Adsorption of Carbon Dioxide by MIL-101(Cr): Regeneration Conditions and Influence of Flue Gas Contaminants
MIL-101(Cr) has drawn much attention due to its high stability compared with other metal-organic frameworks. In this study, three trace flue gas contaminants (H2O, NO, SO2) were each added to a 10 vol% CO2/N2 feed flow and found to have a minimal impact on the adsorption capacity of CO2. In dynamic CO2 regeneration experiments, complete regeneration occurred in 10 min at 328 K for temperature s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Korean Chemical Engineering Research
سال: 2011
ISSN: 0304-128X
DOI: 10.9713/kcer.2011.49.6.764