Cobalt phthalocyanine as a biomimetic catalyst in the amperometric quantification of dipyrone using FIA

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Manganese Phthalocyanine as a Biomimetic Electrocatalyst for Phenols in the Development of an Amperometric Sensor

A construção de um sensor amperométrico para compostos fenólicos usando um eletrodo de pasta de carbono modificado com ftalocianina de manganês e histidina é relatado. Sob condições otimizadas, em 0 mV vs Ag/AgCl numa solução tampão fosfato 0,1 mol dm (pH 7,0) contendo H 2 O 2 250 μmol dm, uma resposta linear para catecol entre 20 e 130 μmol dm, com sensibilidade de 0,56 (± 0,02) μA dm mol cm, ...

متن کامل

Flow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine

A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detec...

متن کامل

the significance of conjunction as a cohesive device in teaching writing

the research questions were as follows: 1. is there any relationship between the students concious awareness of the form and implications of the conjuncations and their improvement in using appropriate conjunctions? 2. does students knowledge of the from and the implications of the conjunctions help them to produce more coherent writings. 3. does a comparison between english conjunctions and th...

15 صفحه اول

flow-injection amperometric determination of ascorbic acid using a graphite-epoxy composite electrode modified with cobalt phthalocyanine

a flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(ii) phthalocyanine (copc) modified graphite-epoxy electrode. the amperometric respons was evaluated with regard to ph, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. the limit of detection...

متن کامل

Tris (2,2?-bipyridil) copper (II) chloride complex: a biomimetic tyrosinase catalyst in the amperometric sensor construction

The use of tris (2,2?-bipyridil) copper (II) chloride complex, [Cu(bipy)3]Cl2 /6H2O, as a biomimetic catalyst, is reported in the construction of an amperometric sensor for dopamine. The sensor was prepared modifying a glassy carbon electrode with a Nafion† membrane doped with the complex. The optimized conditions for the sensor response were obtained in 0.25 mol dm 3 Pipes buffer (pH 7.0) cont...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Talanta

سال: 2011

ISSN: 0039-9140

DOI: 10.1016/j.talanta.2011.07.038