Coherence Function Method for Detecting Inter-Turn Fault in HVDC Converter Transformer

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inter-Turn Fault Detection in Power transformer Using Wavelets

Detection and removal of incipient faults in power transformer winding is essential because minor faults may develop and lead to major faults and finally irretrievable damages occur. This research article presenta a new, simple and incipient fault detection technique, which is based on symmetrical component approach. Using this protection technique, it is possible to detect minor turn-to-turn f...

متن کامل

Modelling and Simulation of a Transformer With Inter-turn Fault Including Saturation Effect and Variable Fault Parameters

This investigation deals with a mathematical model for a distribution transformer including saturation effect. To this end, the equations related to a three phase transformer are specified and the effect of an inter-turn fault is included. Naturally by applying an inter-turn fault the inductance and resistance matrix will change. Thus, unknown quantities of inductances and resistances for compl...

متن کامل

Recognition and Location of Power Transformer Turn to Turn Fault by Analysis of Winding Imposed Forces

Turn to turn fault is one of the major internal failures in the power transformers that if it is not quickly detected, can be extended and led to a complete transformer breakdown. So, the diagnosis and location of the turn to turn fault of the power transformer, as one of the most important equipment in the power system, is the main objective of this paper. For this purpose, a detailed model of...

متن کامل

Requirements for Fault Protection in HVDC Grids

Conventional Voltage Source Converters (VSC) cannot interrupt DC fault currents and DC circuit breakers are not yet commercially available for HVDC power ratings. Thus, the protection of VSC-HVDC systems is still an obstacle for the development of this technology. The features of VSC-HVDC systems make them suitable for implementing HVDC grids. Nevertheless, HVDC grids are more complex than poin...

متن کامل

Inter-turn Fault Analysis of Synchronous Generator using Finite Element Method (FEM)

A turn fault in the stator winding of a generator causes a large circulating current to flow in the shorted turns. If left undetected, turn faults can propagate, leading to phaseground or phase-phase faults. Incipient detection of turn’s faults is essential to avoid hazardous operating conditions and reduce down time. At present the synchronous generators are protected against almost all kind o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering

سال: 2015

ISSN: 2320-3765,2278-8875

DOI: 10.15662/ijareeie.2015.0403036