Collaborative control strategy of power electronic transformer and fault current limiter in DC microgrid
نویسندگان
چکیده
منابع مشابه
Solid State Electronic Fault Current Limiter to Limit the Fault Current in Power System
Increase in power generation capacity of electric power systems has lead to increase in the fault current level which can exceed the maximum designed short-circuit ratings of the switchgear. All the equipment therefore must have a short-circuit rating capable to withstand this level. Short-circuit currents contain extremely high energy and can damage electrical equipment. Typically, the circuit...
متن کاملFlexible Power Electronic Transformer for Power Flow Control Applications
This paper proposes a Flexible Power Electronic Transformer (FPET) for the application in the micro-grids. The low frequency transformer is usually used at the Point of Common Coupling (PCC) to connect the low voltage grid and utility network to each other. The conventional 50Hz transformer results in enhanced low voltage-grid power management system during grid-connected operation. In this pap...
متن کاملControl Design for a Power Electronic Based Fault Current Limiter (FCL)
This paper shows a solution for controlling shortcircuit currents of a power electronic based Fault Current Limiter (FCL). A model for control design of three-phase short-circuit currents will be presented. A way of limiting the maximum aperiodic short-circuit current is derived with special regards to the stability of the entire system. Control designs of singleand two-phase shortcircuit curre...
متن کاملThe Impact of Superconducting Fault Current Limiter Locations on Voltage Sag in Power Distribution System
In this paper, the impacts of installing superconducting fault current limiter (SFCL)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (DG). Among various SFCLs, the hybrid type with a superconducting element in parallel with a current limiting reactor (CLR) is selected. This is more effective than resisto...
متن کاملMitigation Transformer Inrush Current Using Modified Transient Current Limiter
This study presents a modified transient current limiter (MTCL) for mitigation the inrush current of transformers. The MTCL is based on conventional transient current limiter (TCL), which, its configuration is modified to overcome the TCL drawbacks of operation. The proposed MTCL offers lower power losses and voltage/current THD during normal operation mode. It needs only one limiting reactor i...