Collarless polished tapered stem

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Collarless polished tapered stem: clinical and radiological results at a minimum of ten years' follow-up.

We retrospectively reviewed 175 patients (191 hips) who had undergone primary cemented total hip replacement between November 1992 and November 1995 using a collarless polished double-tapered femoral component after a minimum of ten years (mean 11.08; 10 to 12.8). All stems were implanted using contemporary cementing techniques with a distal cement restrictor, pressurised lavage, retrograde cem...

متن کامل

The influence of cement thickness on stem subsidence and cement creep in a collarless polished tapered stem

OBJECTIVES Favourable results for collarless polished tapered stems have been reported, and cement creep due to taper slip may be a contributing factor. However, the ideal cement thickness around polished stems remains unknown. We investigated the influence of cement thickness on stem subsidence and cement creep. METHODS We cemented six collarless polished tapered (CPT) stems (two stems each ...

متن کامل

Initial Evaluation on Subsidence of Cemented Collarless Polished Tapered Stem Applied to the Patients with Narrow Femoral Medullar Canal

PURPOSE The geometry of the proximal femur is one of the important factors for choosing the suitable stem. We have been applied cemented collarless polished tapered (CPT) stem to the patients with small femur. Radiographic evaluation was performed to access the clinical feature of the stem in early stage of the follow-up. METHODS One hundred total hip arthroplasties with CPT system were perfo...

متن کامل

Stem fracture of a collarless, polished, double-taper cemented femoral prosthesis: a case report.

We report a case of stem fracture of a collarless, polished, double-taper cemented stainless steel femoral prosthesis. Scanning electron microscopy showed fatigue striations, indicating failure by fatigue. This case study highlights that stem fracture can still occur with modern implants. Size 0 CPT stem should be avoided in patients with high body mass index. To our knowledge this is the first...

متن کامل

Femoral impaction bone allografting with an Exeter cemented collarless, polished, tapered stem in revision hip replacement: a mean follow-up of 10.5 years.

Femoral impaction bone allografting has been developed as a means of restoring bone stock in revision total hip replacement. We report the results of 75 consecutive patients (75 hips) with a mean age of 68 years (35 to 87) who underwent impaction grafting using the Exeter collarless, polished, tapered femoral stem between 1992 and 1998. The mean follow-up period was 10.5 years (6.3 to 14.1). Th...