منابع مشابه

Dynamic magnification factors of SDOF oscillators under harmonic loading

The magnification factor for the steady-state response of a SDOF system under harmonic loading is described in many structural dynamics textbooks; the well known analytical solution is easily obtained from the solution to the damped equation of motion for harmonic loading. The complete and steady state solutions can differ significantly. An analytical expression for the maximum response to the ...

متن کامل

Seismic Response of Steel Framed Hospital Buildings with Self-Centering Systems (2004-2005)

This paper introduces the concepts of Elasto-Plastic Systems (EPS) and Self-Centering Systems (SCS) for the seismic design of steel-framed hospital buildings. Redesign of the MCEER West Coast Demonstration Hospital with SCS is conducted using this approach. An ensemble of 25 simulated MCEER Ground Motions having a probability of exceedence of 5% in 50 years in Northridge, California is used as ...

متن کامل

Performance of Glass Panels Under Seismic Loading

The primary goal of this thesis is to analyze current trends in the improvement of the performance and safety of glass during an earthquake. The four sections consist of an overview of glass as a building material, glass installation methods, rehabilitation methods for existing structures, and building code related issues. The thesis is based on an analysis of sources including books, journal a...

متن کامل

A COMPARATIVE STUDY OF OPTIMUM AND IRANIAN SEISMIC DESIGN FORCE DISTRIBUTIONS FOR STEEL MOMENT RESISTING BUILDINGS

In this study, constant-ductility optimization algorithm under a family of earthquake ground motions is utilized to achieve uniform damage distribution over the height of steel moment resisting frames (SMRFs). SMRF structures with stiffness-degrading hysteric behavior are modeled as single-bay generic frame in which the plastic hinge is confined only at the beam ends and the bottom of the first...

متن کامل

Active Tendons for Seismic Control of Buildings

In this study, active tendons with Proportional Integral Derivation type controllers were applied to a SDOF and a MDOF building model. Physical models of buildings were constituted with virtual springs, dampers and rigid masses. After that, equations of motion of all degrees of freedoms were obtained. Matlab Simulink was utilized to obtain the block diagrams for these equations of motion. Param...