Combined effect of teriparatide and low-intensity pulsed ultrasound for nonunion: a case report
نویسندگان
چکیده
منابع مشابه
Successful treatment of nonunion in severe finger injury with low-intensity pulsed ultrasound (LIPUS): a case report
INTRODUCTION Severe injuries of the hand or single fingers require immediate treatment but surgical fixation methods are limited depending on soft tissue damage. Thus, it is very common that severe soft tissue damage along with poor osteosynthetic bone fixation results in a delayed healing process or nonunion. Low-intensity pulsed ultrasound (LIPUS) has been proven to stimulate bone formation i...
متن کاملLOW INTENSITY PULSED ULTRASOUND TREATMENT INCREASES RABBIT RADIAL FRACTURE HEALING
In order to study the effect of ultrasound (US) on bone healing, a complete transverse fracture was made in the right radius of adult male rabbits by a cutter. 52 rabbits were used: group I. control (n= 17): group 2. test (n:=: 15): group 3, intact (n= I) and group 4 (n= 12) who were examined only for evaluation of the cutter effects in detail. 7 animals were operated with a Gigli saw. The ...
متن کاملLow Intensity Pulsed Ultrasound (LIPUS)
The application of ultrasound energy at much lower levels than is the current clinical norm is starting to gain ground as a therapeutic possibility. Clearly the applied energy is the same, it is the ‘dose’ which is different – most importantly, the intensity (W cm) – which is MUCH lower – typically 2 or 3 times lower than the lowest setting on most regular clinical machines, with the most commo...
متن کاملLow Intensity Pulsed Ultrasound (LIPUS)
The application of ultrasound energy at much lower levels than is the current clinical norm is starting to gain ground as a therapeutic possibility. Clearly the applied energy is the same, it is the ‘dose’ which is different – most importantly, the intensity (W/cm) – which is MUCH lower – typically 2 or 3 times lower than the lowest setting on most regular clinical machines, with the most commo...
متن کاملTHE BEST DURATION OF LOW INTENSITY PULSED ULTRASOUND FOR ACCELERATING FRACTURED-RADIAL BONE REPAIR
We have already shown that low intensity pulsed ultrasonic treatment increases rabbit radial fracture healing. The present experiment was undertaken to find out the best duration for treatment. A complete transverse fracture was made in the right radial bones of21 adult male rabbits by a Stanley knife. The animals were divided into 4 groups: group 1, control groups 2, 3, and 4, experimental...