k-t BLAST reconstruction from arbitrary k-t space sampling: application to dynamic radial imaging
M. S. Hansen, J. Tsao, S. Kozerke, H. Eggers MR-Centre, Skejby Hospital, Aarhus University Hospital, Aarhus N, Denmark, Novartis Institutes for BioMedical Research, Cambridge, Massachusetts, United States, Institute for Biomedical Engineering, Swiss Federal Institute of Technology (ETH), Zurich, Switzerland, Philips Research Laboratories, Hamburg, Germany INTRODUCTION The k-t BLAST method (1) d...
متن کاملAn Auto-Calibrated k-t Approach for Fast 3D Dynamic Contrast-Enhanced Abdominal Imaging
INTRODUCTION: Dynamic contrast-enhanced (DCE) MRI can provide noninvasive visualization of contrast agent uptake and has been gaining increasing notice in tissue characterization. However, its ability to provide high-temporal-resolution delineation of contrast kinetics remains limited by the long scan time needed for high-definition volumetric imaging. Recent advances in fast imaging could lead...
متن کاملSimultaneous T2 and T2* dynamic susceptibility contrast perfusion imaging using a multi-echo parallel imaging approach
Introduction. The utility of multi-echo DSC with gradient echo (GRE) EPI has recently been demonstrated for improved AIF determination, T1 independent contrast concentration estimation, and SNR recovery. In order to quantify the difference between the static and dynamic dephasing regimes, a gradient and spin echo (GRASE) multi-shot multi-echo EPI sequence is demonstrated. The hemodynamic parame...
متن کاملstatistical inference via empirical bayes approach for stationary and dynamic contingency tables
چکیده ندارد.
15 صفحه اولL1k-t ESPIRiT: Accelerating Dynamic MRI Using Efficient Auto-Calibrated Parallel Imaging and Compressed Sensing Reconstruction
Background Iterative self-consistent parallel imaging (PI) reconstruction (SPIRiT) [1, Lustig M, MRM 64:457-71,2010] has been extended for dynamic imaging by exploiting temporal correlations in k-t space (k-t SPIRiT) [2,Santelli C, MRM 72:1233-45, 2014]. Using eigendecomposition of a modified SPIRiT operator, computationally optimized reconstruction formally translates into auto-calibrated SENS...