Combining phase images from array coils using a short echo time reference scan ( COMPOSER )
نویسندگان
چکیده
منابع مشابه
Combining phase images from array coils using a short echo time reference scan (COMPOSER)
PURPOSE To develop a simple method for combining phase images from multichannel coils that does not require a reference coil and does not entail phase unwrapping, fitting or iterative procedures. THEORY AND METHODS At very short echo time, the phase measured with each coil of an array approximates to the phase offset to which the image from that coil is subject. Subtracting this information f...
متن کاملField mapping without reference scan using asymmetric echo-planar techniques.
Improvements in Bo mapping and shimming were achieved by measuring the static field information in multiple subsequent echoes generated by an asymmetric echo-planar readout gradient train. With careful compensation, eddy current effects were shown to affect the adjustment of the shim coils minimally. In addition to reducing the time required for field mapping by two-fold, the sensitivity was si...
متن کاملPhased array antenna using MEMS phase shifter
This article presents a phased array antenna employing MEMS phase shifter. The proposed phased array antenna consists of eight square patch antennas operating at 10.4 GHz with a bandwidth of 400 MHz. Feed line for each patch passes through a MEMS phase shifter realized by a series of bridges above the transmission line. The distance between the bridge and the transmission line underneath it is ...
متن کاملCluster-based segmentation of dual-echo ultra-short echo time images for PET/MR bone localization
BACKGROUND Magnetic resonance (MR)-based attenuation correction is a critical component of integrated positron emission tomography (PET)/MR scanners. It is generally achieved by segmenting MR images into tissue classes with known attenuation properties (e.g., bone, fat, soft tissue, lung, air). Ultra-short echo time (UTE) have been proposed in the past to locate bone tissue. In this study, tri-...
متن کاملCombining time DEA scores using a dynamic panel data model
We define a combined DEA score to evaluate efficiency in agricultural research. The production model we propose considers efficiency measurements under variable returns to scale for each year in the period 2012–2017. We postulate a first-order autoregressive process in the presence of covariates, to explain efficiency. Powers of the autocorrelation coefficient estimated assuming a dynamic panel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Magnetic Resonance in Medicine
سال: 2015
ISSN: 0740-3194,1522-2594
DOI: 10.1002/mrm.26093