Abstract In 2018 the high energy X-ray beamlines P07[1] and P21b[2] at DESY’s storage ring PETRA III received new undulators. The two identical devices were built by an industry collaboration of Research Instruments GmbH Kyma S.p.A. according to specifications. They have a magnetic length 4 m, period 21.2 mm deflection parameter K 1.41 gap 7.0 mm. We report about experience during magnet tuning, final acceptance measurements commissioning in accelerator tunnel.
منابع مشابه
In-vacuum Undulators
The so-called in-vacuum undulators, in which magnet arrays are installed inside the vacuum chamber, have been proved to be a promising way toward shorter wavelength of synchrotron radiation (SR). Especially, it has been adopted in lots of medium-scale SR facilities to provide angstrom x rays to carry out protein-crystallography experiments. Needless to say, there have been a number of technical...
متن کاملCommissioning Results and Improvements of the Machine Protection Sytem for Petra Iii
PETRA III is a high brilliant synchrotron light-source operating at 6GeV. The commissioning of the machine had started in April 2009 [1]. In the first months of operation the Machine Protection System (MPS) ran on basic MPS requirements to protect absorbers and vacuum chambers in the damping wiggler section and the undulator section against synchrotron light. Therefore several alarms distribute...
متن کاملCommissioning Experience with Caribu
The Californium Rare Ion Breeder Upgrade (CARIBU) of the ATLAS superconducting linac facility aims at providing low-energy and reaccelerated neutron-rich radioactive beams to address key nuclear physics and astrophysics questions. These beams are obtained from fission fragments of a Cf-252 source, thermalized and collected into a low-energy particle beam by a helium gas catcher, mass analyzed b...
متن کاملNsls In-vacuum Undulators and Mini-beta Straights
We review the work carried out in the X13 R&D Straight Section of the NSLS X-Ray Ring on small gap in-vacuum undulators (IVUNs). Then we discuss: (1) plans to replace the pure permanent magnet undulator in X13 by a hybrid design providing stronger magnetic fields, enhancing the tunability of the device; (2) plans to install hybrid IVUNs in the two RF straights of the X-Ray Ring, increasing the ...
متن کاملElectromagnetic Simulations for the PETRA III BPMs
1.1. PETRA III: PETRA III is a new high-brilliance synchrotron radiation source to be built at DESY, Hamburg [1]. Planned to start operation in 2009, the facility will have 14 beam lines spread along one eighth of its circumference. 40 to 960 bunches with a current of 100 mA and an emittance of 1 nm·rad will be circulated at 6 GeV. The topping up operation will ensure a stable beam. 235 beam po...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of physics
سال: 2022
ISSN: ['0022-3700', '1747-3721', '0368-3508', '1747-3713']
DOI: https://doi.org/10.1088/1742-6596/2380/1/012021