Committed DVI pacing

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ventricular tachycardia produced by a normally functioning AV sequential demand (DVI) pacemaker with "committed" ventricular stimulation.

A variety of pacemaker-induced arrhythmias has been observed with the introduction of new cardiac pacing modes (1). With the advent of atrioventricular (AV) sequential demand (DVI) pacemakers, the electrocardiographic features associated with their normal operation have been studied and reported (2). In this report, we describe an abnormal event: the induction of ventricular tachycardia by a no...

متن کامل

D:bishtopeman ̈ ̈.dvi

Most experts agree that a learning organization whose employees have a clear vision of the importance of service quality and are motivated to provide that quality will achieve superior service quality. We develop a theoretical framework and conduct a cross-sectional empirical study to investigate the inter-relationships among these constructs. The results indicate that higher levels of both emp...

متن کامل

19 August 2013.dvi

The amalgamation property (AP) is of particular interest in the study of residuated lattices due to its relationship with various syntactic interpolation properties of substructural logics. There are no examples to date of non-commutative varieties of residuated lattices that satisfy the AP. The variety SemRL of semilinear residuated lattices is a natural candidate for enjoying this property, s...

متن کامل

D:bishtaca 92 92.dvi

10 Quantification of electroinactive dopants in conductive polypyrrole (PPY) films was performed with electrochemistry combined on-line with inductively coupled plasma-atomic emission spectrometry (EC/ICP-AES). Anion (HSO4−) ejection out of a PPY film was first chosen as a model system and the results obtained with EC/ICP-AES were found to be comparable with values deduced by electrochemical qu...

متن کامل

C:tonypapersfcc Papersdemartinisswp1054.dvi

In this paper we present a new improved design for multi-object auctions and report on the results of tests of that design. We merge the better features of two extant but very different auction processes, the Milgrom FCC design (see Milgrom (1995)) and the Adaptive User Selection Mechanism (AUSM) of Banks et al. (1989)). Then, by adding one crucial new feature, we are able to create a new desig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the American College of Cardiology

سال: 1983

ISSN: 0735-1097

DOI: 10.1016/s0735-1097(83)80323-4