منابع مشابه
A versatile compact array calibrator for UHE neutrino acoustic detection
In situ acoustic calibration devices are necessary to assure the optimal performance of sensors and detectors for the acoustic detection of ultra-high energy neutrinos in underwater telescopes. Moreover, they provide evidences for the feasibility evaluation of the technique and for the determination of the entire detector efficiency. Following previous studies related to parametric acoustic sou...
متن کاملRadiometric measurements of the microwave emissivity of foam
Radiometric measurements of the microwave emissivity of foam were conducted in May 2000 at the Naval Research Laboratory’s Chesapeake Bay Detachment using radiometers operating at 10.8 and 36.5 GHz. Horizontal and vertical polarization measurements were made at 36.5 GHz; horizontal, vertical, +45, 45, left circular, and right circular polarization measurements were obtained at 10.8 GHz. Surface...
متن کاملRadiometric Measurements of the Microwave Emissivity of Reproducible Breaking Waves
In a recent experiment the microwave emissivity of foam on calm water was measured to be 0.75 to 0.95 and dependent on polarization [1]. Microwave radiometric measurements of breaking waves on the open ocean showed that the emission due to wave breaking varies with the time dynamics of the wave, as well as with radiometer polarization and viewing angle [2]. However, the inherent intermittency a...
متن کاملRainfall estimation using spaceborne microwave radar and radiometric measurements
The present paper deals with some of the recent remote sensing techniques for the estimation of rainfall, mainly from passive and active microwave measurements from space. The sensitivity analysis based on forward approach following the radiative transfer modelling using data from ECMWF and mesoscale models is presented. The inverse methods of retrieving rainfall from satellite microwave measur...
متن کاملCompact Relativistic Millimeter-Band Microwave Oscillators
1 This work was supported in part by RFBR, Grants: 05-02-08016; 04-02-16576; 05-02-08240. Abstract – The report presents a brief review of research and developments, which made it possible to create during the number of years a series of the pulse-periodic millimeter wave range nanosecond and subnanosecond relativistic HPM generators. The devices are based on a compact high-current electron acc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Review of Scientific Instruments
سال: 2006
ISSN: 0034-6748,1089-7623
DOI: 10.1063/1.2209960