Compact soft-X-ray lasers.
نویسندگان
چکیده
منابع مشابه
Optimum driving a Z-pinch for soft X-Ray lasers
A capillary plasma z-pinch as an alternative active medium of soft X-Ray lasers was studied experimentally and theoretically. The theoretical analysis was based on the self consistent solution of the so called “snow plow” model. The dynamics of pinched plasma is determined by the capillary parameters and by the time dependence of electrical current passing through it. The current time dependenc...
متن کاملExtremely compact soft X-ray lasers based on capillary discharges
Extremely compact high repetition rate soft X-ray lasers based on capillary discharge excitation have demonstrated average powers of a few milliWatt at 46.9 nm, milli-Joule-level pulse energy, peak spectral brightness several orders of magnitude larger than third-generation synchrotron beam lines, and excellent spatial coherence. Examples of the use of a capillary discharge soft X-ray laser in ...
متن کاملTable-top soft x-ray lasers
This article reviews the progress in the development of practical table-top sources of soft x-ray laser radiation. The field is rapidly approaching the stage at which soft x-ray lasers sufficiently compact to fit onto a normal optical table will be routinely utilized in science and technology. This is the result of recent advances in the amplification of soft x-ray radiation in both compact las...
متن کاملApplication of extremely compact capillary discharge soft x-ray lasers to dense plasma diagnostics
Table-top capillary discharge soft x-ray lasers combine the advantages of a small size and a high repetition rate with an extremely high brightness similar to that of their laboratory-size predecessors. When utilized to probe high density plasmas their short wavelength results in a higher critical density, reduced refraction, decreased free-electron absorption, and higher resolution as compared...
متن کاملProbing High Density Plasmas with Soft X-Ray Lasers
Collisionally pumped x-ray lasers are ideal for a wide variety of plasma diagnostics. They have been demonstrated over a wavelength range extending from 3.5 nm to 40 nm and have output energies as high as 10 mJ in 150 ps pulses. The beam divergence is less than 15 mrad and the linewidth λ/∆λ~10 provides sufficient longitudinal coherence for interferometry. Using various arrangements constructed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Review of Laser Engineering
سال: 1990
ISSN: 0387-0200,1349-6603
DOI: 10.2184/lsj.18.11_871