Comparative clinical study of pulsatile and non-pulsatile perfusion in 350 consecutive patients.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical comparison of pulsatile and nonpulsatile perfusion during cardiopulmonary bypass.

Controversy exists concerning the utilization of pulsatile flow during cardiopulmonary bypass (CPB) with regard to improved patient outcomes. The purpose of the present study was to evaluate pulsatile perfusion in patients undergoing CPB in a clinical setting. Seventy patients undergoing open heart surgery for repair of valvular or congenital heart disease were prospectively entered into the st...

متن کامل

A Mathematical Cardiovascular Model with Pulsatile and Non-pulsatile Components

In this study, two existing mathematical cardiovascular models, a non-pulsatile global model and a simplified pulsatile left heart model were investigated, modified and combined. A global lumped compartment cardiovascular model was developed that could predict the pressures in the systemic and pulmonary circulation, and specifically the pulsatile pressures in the the finger arteries where real-...

متن کامل

Design, Evaluation and Comparative Study of Pulsatile Release from Tablet and Capsule Dosage Forms

      The objective of present research was to design, evaluate and compare drug release from two different dosage forms in pulsatile drug delivery system (DDS) for Metoprolol tartarate (MT) as tablet and capsule. Pulsatile systems are gaining a lot of interest as they deliver the drug at the right site of action at the right time and in the right amount, thus providing spatial and temporal del...

متن کامل

Effect of pulsatile flow perfusion on decellularization

BACKGROUND Decellularized animal organs have been used as scaffolds for tissue engineering. To make a properly functioning scaffolds, the extracellular matrix (ECM) components must be preserved after decellularization. Because pulsatile flow is known to be beneficial for tissue perfusion, pulsatile perfusion of a detergent might decrease the exposure time of the tissues to the detergent used fo...

متن کامل

a comparative study of the relationship between self-, peer-, and teacher-assessments in productive skills

تمایل به ارزیابی جایگزین و تعویض آن با آزمون سنتی مداد و کاغذ در سالهای اخیر افزایش یافته است. اکثر زبان آموزان در کلاس های زبان از نمره نهایی که استاد تعیین میکند ناراضی اند. این تحقیق جهت بررسی ارزیابی در کلاس های زبان انگلیسی به هدف رضایتمندی زبان آموزان از نمره هایشان انجام گرفته است که در آن نمرات ارائه شده توسط سه گروه ارزیاب (ارزیابی خود دانشجو، همسالان واستاد) در مهارت های تولید (تکل...