Comparative evaluation of BACTEC MGIT 960 with BACTEC 9000 MB and LJ for isolation of mycobacteria in The Gambia.
BACKGROUND The BACTEC MGIT 960 was evaluated and compared with BACTEC 9000 MB and Lowenstein-Jensen medium for recovery rate of mycobacteria, time to detection, and contamination rate. METHODOLOGY 147 sputum samples obtained from patients with suspicion of tuberculosis were processed and inoculated into BACTEC MGIT 960, BACTEC 9000 MB and Lowenstein-Jensen medium using standardized procedures...
متن کاملMeta-analysis of BACTEC MGIT 960 and BACTEC 460 TB, with or without solid media, for detection of mycobacteria.
In a meta-analysis of 10 studies, the BACTEC 960/MGIT and BACTEC 460 systems showed a sensitivity and specificity in detecting mycobacteria (1,381 strains from 14,745 clinical specimens) of 81.5 and 99.6% and 85.8 and 99.9%, respectively. Combined with solid media, the sensitivity of the two systems increased to 87.7 and 89.7%, respectively.
متن کاملMulticenter evaluation of the BACTEC MGIT 960 system for recovery of mycobacteria.
We evaluated the BACTEC MGIT 960 system, which is a fully automated, noninvasive system for the growth and detection of mycobacteria with a capacity to incubate and continuously monitor 960 7-ml culture tubes. We studied 3,330 specimens, 2,210 respiratory and 1,120 nonrespiratory specimens, collected from 2,346 patients treated at six sites. Processed specimens were inoculated into the BACTEC M...
متن کاملComparison of the BACTEC MGIT 960 and BACTEC 460TB systems for detection of mycobacteria in clinical specimens.
The reliability of the Mycobacteria Growth Indicator Tube (MGIT) 960 system for rapid detection of mycobacteria in clinical specimens was evaluated and compared to the radiometric method (BACTEC 460TB) and to mycobacterial culture on Lowenstein-Jensen (LJ) medium. Clinical specimens (n = 590) were tested without selection. A total of 121 (20.5%) isolates of mycobacteria were recovered; 98 (81.0...
متن کاملComparison of BACTEC MGIT 960 system and BACTEC 460 TB system for growth and detection of Mycobacteria from clinical specimens.
This study was carried out to compare the performance of BACTEC MGIT 960 with the BACTEC 460 TB for growth and detection of Mycobacteria from human clinical specimens. The BACTEC MGIT 960 instrument is a fully automated system that utilizes MGIT tubes containing an oxygen sensor embedded in silicon at the bottom and filled with 7 mL of modified Middlebrook 7H9 broth. Identical samples were inoc...