Comparison between Fastpac and conventional Humphrey perimetry

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical comparison of frequency doubling technology perimetry and Humphrey perimetry.

AIM To determine the number of missed points on frequency doubling technology (FDT) perimetry that optimise the sensitivity and specificity of the test and to determine the topographical accuracy of the test in a clinical setting. METHODS In a prospective study, the perimetric data from 99 patients who underwent both FDT perimetry in the screening mode and Humphrey 24-2 (H24-2) were used to d...

متن کامل

Comparison of Octopus Semi-Automated Kinetic Perimetry and Humphrey Peripheral Static Perimetry in Neuro-Ophthalmic Cases

Aim. To compare semikinetic perimetry (SKP) on Octopus 900 perimetry to a peripheral static programme with Humphrey automated perimetry. Methods. Prospective cross-section study comparing Humphrey full field (FF) 120 two zone programme to a screening protocol for SKP on Octopus perimetry. Results were independently graded for presence/absence of field defect plus type and location of defect. Re...

متن کامل

Different strategies for Humphrey automated perimetry: FASTPAC, SITA standard and SITA fast in normal subjects and glaucoma patients.

PURPOSE To evaluate the influence on examination time and test quality of the recently introduced SITA strategies of the Humphrey Field Analyzer. METHODS The sample consisted of 41 subjects (19 normal subjects and 22 glaucoma patients), all experienced in automated perimetry, ranging in age from 24 to 83 years. One eye of each patient was examined with the HC30-2 program using the FASTPAC (FP...

متن کامل

A comparison between Humphrey and frequency doubling perimetry for chiasmal visual field defects.

PURPOSE To evaluate and compare the diagnostic ability of frequency doubling technology perimetry (FDT) with standard automated perimetry (SAP) using Humphrey Field Analyser for the detection of visual field defects produced by chiasmal lesions. METHODS Fifteen patients with documented chiasmal disease and previously diagnosed of bitemporal hemianopia with Humphrey perimetry were prospectivel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Australian and New Zealand Journal of Ophthalmology

سال: 1994

ISSN: 0814-9763,1440-1606

DOI: 10.1111/j.1442-9071.1994.tb00773.x