Comparison between Subsequent Irradiation and Co-Irradiation into SIMP Steel
نویسندگان
چکیده
منابع مشابه
Co Irradiation Chamber
Due to its excellent remote measurability and high spatial resolution, the fiber optic-based radiation dosimeter has been extensively explored for its usability in medical applications by several researchers [1-2]. In the previous work [3,4], we reported the result of our investigation on feasibility of a photon dosimeter constructed with a BGO(Bi4Ge3O12) or GSO(Gd2SiO5) scintillator piece coup...
متن کاملEvaluation of Irradiation Hardening of P92 Steel under Ar Ion Irradiation
P92 steel was irradiated with Ar ion up to 10 dpa at 200, 400, and 700 ◦C. The effect of Ar ion irradiation on hardness was investigated with nanoindentation tests and microstructure analyses. It was observed that irradiation-induced hardening occurred in the steel after Ar ion irradiation at all three temperatures to 10 dpa. The steel exhibited significant hardening at 200 and 700 ◦C, and slig...
متن کاملBiological Dosimetry of Co-60 Gamma Irradiation.
Development of radiation technology has resulted in increasing numbers of people working with it. Therefore it has increasingly been important to monitor the radiation in order to ensure public safety. Physical dosimetry plays an important role in monitoring. But a need arise for biological dosimetry where physical dosimetry is absent or its presence is insufficient. In this study Co-60 gamma r...
متن کاملIMRT for Craniospinal Irradiation: A Dosimetric Comparison
Part of the Oncology Commons This Article is brought to you for free and open access by the Jefferson Digital Commons. The Jefferson Digital Commons is a service of Thomas Jefferson University's Center for Teaching and Learning (CTL). The Commons is a showcase for Jefferson books and journals, peer-reviewed scholarly publications, unique historical collections from the University archives, and ...
متن کاملCo Gamma Irradiation - A Combined Computational and Experimental Study
Radiolysis of sulfamethoxazole (SMX) was investigated in aqueous samples with different initial conditions: [SMX]0 (20 μM ÷ 140 μM), pH0 (2.0 ÷ 11.0), [H2O2]0 (0 ÷ 10 mM) and absorbed doses (D, 0.3 kGy ÷ 5.0 kGy). Five transformation products (TPs) of SMX were experimentally identified and evaluated using HPLC/UV and LC-QTOF-MS, respectively. Compared to the precursor SMX, they possess higher p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Materials
سال: 2021
ISSN: 1996-1944
DOI: 10.3390/ma14061393