Comparing performance of ProSeal laryngeal mask airway and I-gel in anesthetized adult patients
With great interest, we read the recent article by Ekinci et al1 comparing the performance of ProSeal laryngeal mask airway (PLMA) and I-gel in anesthetized adult patients. They showed that insertion was easier, insertion time was shorter, success rate of nasogastric tube insertion was higher, and complications were fewer with the I-gel compared to the PLMA. However, we note other issues of thi...
متن کاملComparisons of clinical performance of guardian laryngeal mask with laryngeal mask airway ProSeal
BACKGROUND The Guardian Laryngeal Mask Airway (G-LMA) is a new silicone-based single-use extraglottic device with the drainage port and a cuff pilot valve with pressure indicator. The aim of this study is to compare the clinical performance of this laryngeal mask airway with ProSeal laryngeal mask airway (P-LMA). METHODS In this prospective randomized study, we included adult patients with AS...
متن کاملComparison of the i-gel™ and the Laryngeal Mask Airway Classic™ in terms of clinical performance.
PURPOSE The i-gel™ is one of the second generation supraglottic airway devices. Our study was designed to compare the i-gel and the Laryngeal Mask Airway Classic™ with respect to the clinical performance. METHODS We compared the performance of the i-gel with that of the Laryngeal Mask Airway Classic in 120 patients undergoing urologic surgery during general anesthesia without muscle relaxant ...
متن کاملComparison of the standard laryngeal mask airway and the ProSeal laryngeal mask airway in obese patients.
BACKGROUND The ProSeal laryngeal mask airway (PLMA) may have advantages over the laryngeal mask airway (LMA) in obese patients. We tested this hypothesis in a clinical setting. METHODS Sixty obese patients (BMI >30) were randomized to receive mechanical ventilation (tidal volume 7 ml kg(-1), PEEP 10 cm H(2)O), through either the PLMA or the LMA. A gastric tube was used in all patients. Cuff p...
متن کاملComparison of Supreme Laryngeal Mask Airway and ProSeal Laryngeal Mask Airway during Cholecystectomy.
OBJECTIVE This study compared the safety and efficacy of the Supreme Laryngeal Mask Airway (S-LMA) with that of the ProSeal-LMA (P-LMA) in laparoscopic cholecystectomy. MATERIAL AND METHODS Sixty adults were randomly allocated. Following anaesthesia induction, experienced LMA users inserted the airway devices. RESULTS Oropharyngeal leak pressure was similar in groups (S-LMA, 27.8±2.9 cmH2O;...