Comparison of commercial thermoluminescent readers regarding high-dose high-temperature measurements
نویسندگان
چکیده
منابع مشابه
Performance of thermoluminescent materials for high dose dosimetry
Cases involving high-doses of ionizing radiation are becoming increasingly common.The objective of this work was to characterize thermoluminescent materials for the dosimetry of workers exposed to high doses. Samples of TLD-200, TLD-400 and TLD-800 pellets from Thermo Electron Corporation were studied in gamma high-doses. Dose-response curves were obtained for doses between 100 mGy and 100 Gy. ...
متن کاملRandomized comparison of vaginal dinoprostone and high dose oxytocin of
Introduction: Unripe cervix is the most important factor in failure of labor induction. This study is conducted to compare the efficacy and side effects of Dinoproston and high dose Oxytocin as ripening agents in labor induction. Methods: In this double blinded randomized clinical trial, 120 women with unfavorable cervix who underwent labor induction were randomly assigned to vaginal Dinopros...
متن کاملInterlaboratory Comparison on High-Temperature Superconductor Critical-Current Measurements
An extensive interlaboratory comparison was conducted on high temperature superconductor (HTS) critical-current measurements. This study was part of an international cooperative effort through the Versailles Project on Advanced Materials and Standards (VAMAS). The study involved six U.S. laboratories that are recognized leaders in the field of HTS. This paper includes the complete results from ...
متن کاملDose measurements in intraoral radiography using thermoluminescent dosimeters
The use of X-ray in medicine demands to expose the patient and the professional to the lowest radiation doses available in agreement with ALARA philosophy. The reference level for intraoral dental radiography is 7 mGy and, in Mexico, a number of examinations of this type are performed annually. It is considered that approximately 25% of all the X-rays examinations carried out in our country cor...
متن کاملHIGH TEMPERATURE ELASTIC PROPERTIES OF REFRACTORY MATERIALS
Abstract: A pulse-echo technique, based on ultrasonic "long-bar" mode (LBM) velocity measurements, working up to 1700°C is described. Magnetostrictive transducers and ultrasonic lines used in a 40-85 kHz frequency range are detailed. The conditions of choice of fundamental parameters (frequency, line geometry, sample size) are discussed in relation with the nature and the microstructure of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiation Measurements
سال: 2014
ISSN: 1350-4487
DOI: 10.1016/j.radmeas.2014.04.020