Comparison of measured Serum Total Carbon Dioxide with calculated Bicarbonate calculated from Arterial Blood Gas Analysis

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Discrepancy between Measured Serum Total Carbon Dioxide Content and Bicarbonate Concentration Calculated from Arterial Blood Gases

Large differences between the concentrations of serum total carbon dioxide (TCO2) and blood gas bicarbonate (HCO3 (-)) were observed in two consecutive simultaneously drawn sets of samples of serum and arterial blood gases in a patient who presented with severe carbon dioxide retention and profound acidemia. These differences could not be explained by the effect of the high partial pressure of ...

متن کامل

Comparing measured total carbon dioxide and calculated bicarbonate.

INTRODUCTION The objective of the study is to determine the level of agreement between measured total carbon dioxide (TCO2) and calculated bicarbonate (HCO3-) in our laboratory. MATERIALS AND METHODS TCO2 and HCO3- values of 1820 samples drawn at the same time from the patient were compared. TCO2 from venous samples was measured on Dimension RxL while HCO3- was obtained from arterial blood ga...

متن کامل

Discordance between measured and calculated total carbon dioxide.

Recent studies on the agreement and correlation between measured and calculated total CO2 (TCO2) have yielded conflicting results. Pre-analytical variation could have been partially responsible. While keeping such variables at an absolute minimum, we found excellent correlation (r = 0.98) in 88 samples, with only a small variation in agreement between measured and calculated TCO2 values (SD = 1...

متن کامل

Comparison of Measured Osmolalities with Calculated Osmolalities

CLINICALCHEMISTRY,Vol. 30, No. 10, 1984 1703 13. Cornelis R, Versieck J, MesaL, et al. The ultra-trace element vanadium in human serum. Biol Trace Element Res 3, 257-263 (1981). 14. Bello-Reuss EN, Grady TP, Mazumbar DC. Serum vanadium levels in chronic renal disease. Ann Intern Med 91, 743 (1979). 15. Prost EL, Hunt DP, Walderhaug MD, et al. Vanadium compounds in relation to inhibition of sodi...

متن کامل

Comparison of Calculated with Measured Dynamic

The measured dynamic aperture of the HERA proton ring and the value expected from simulation studies agree within a factor of 2. A better agreement is achieved if a realistic tune modulation is included in the simulation. The approximate threshold of tune-modulation induced diffusion can be calculated analytically. Its value is in remarkable agreement with the dynamic aperture measured. The cal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Indian journal of Medical Biochemistry

سال: 2017

ISSN: 0972-1207,2456-5164

DOI: 10.5005/jp-journals-10054-0025