Comparison of plasma propofol concentration for apnea, response to mechanical ventilation, and airway device between endotracheal tube and supraglottic airway device in Beagles

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries

Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...

متن کامل

the effects of endotracheal tube and i-gel® supraglottic airway device on respiratory impedance: a prospective observational study

background the forced oscillation technique (fot) is a non-invasive means of measuring respiratory resistance and reactance. we tested our hypothesis that endotracheal intubation would cause more substantial preoperative increases in fot parameters than a supraglottic airway device (sgd). methods forty patients requiring general anesthesia and mechanical ventilation for transurethral bladder tu...

متن کامل

success rate of airway devices insertion: laryngeal mask airway versus supraglottic gel device

results in the i-gel group, the success rate was 66.7% for placement on the first attempt, 16.7% for the second, and 3.33% for the third attempt. in the lma group, the success rates were 80.6% and 12.9% for the first and second attempts, respectively. failure in placement occurred in four cases in the i-gel and two cases in lma groups. the mean insertion time was not significantly different bet...

متن کامل

The Effects of Endotracheal Tube and i-gel® Supraglottic Airway Device on Respiratory Impedance: A Prospective Observational Study

BACKGROUND The forced oscillation technique (FOT) is a non-invasive means of measuring respiratory resistance and reactance. We tested our hypothesis that endotracheal intubation would cause more substantial preoperative increases in FOT parameters than a supraglottic airway device (SGD). METHODS Forty patients requiring general anesthesia and mechanical ventilation for transurethral bladder ...

متن کامل

Comparison between supraglottic airway devices and endotracheal tubes in patients undergoing laparoscopic surgery

BACKGROUND Comparisons between the efficacies of supraglottic airway devices (SGAs) and endotracheal tubes (ETTs) in patients undergoing laparoscopic surgeries have yielded conflicting results. Therefore, in this meta-analysis, we compared the clinical performance and incidence of complications between SGAs and ETT intubation in laparoscopic surgery. METHODS A comprehensive search was conduct...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Veterinary Medical Science

سال: 2018

ISSN: 0916-7250,1347-7439

DOI: 10.1292/jvms.17-0468