Comparison of retentive forces between telescopic crowns made of poly(ether ether ketone) and type 4 gold alloy
نویسندگان
چکیده
In this study, retentive forces were compared between telescopic crowns (TSC) made with poly(ether ether ketone) (PEEK) using computer-aided design and manufacturing type 4 gold alloy the conventional method. The of TSCs evaluated by performing a pull-out test primary secondary crowns. Initial force was approximately 12 N for both PEEK TSCs. TSC 6.5 after 10,000 cycles insertion removal. reduction rate in smaller TSC. displayed greater surface roughness on crown to Surface slightly increased at cervical margin repetitive than TSC, however adequate stabilizing dental prostheses even cycles.
منابع مشابه
the investigation of the relationship between type a and type b personalities and quality of translation
چکیده ندارد.
Reconstruction of frontal bone using specific implant polyether-ether-ketone.
Defects on the craniofacial complex may result in aesthetic defects, functional damage, and psychologic consequences. Previously, surgeons showed no interest in reconstructing the operated area, but in the treatment of the problem, leaving bone contour is a secondary issue. Nowadays, area reconstruction with post-reestablishment of contour and local shape has become one of the surgeon's priorit...
متن کاملLocal deformation behavior of surface porous polyether-ether-ketone.
Surface porous polyether-ether-ketone has the ability to maintain the tensile monotonic and cyclic strength necessary for many load bearing orthopedic applications while providing a surface that facilitates bone ingrowth; however, the relevant deformation behavior of the pore architecture in response to various loading conditions is not yet fully characterized or understood. The focus of this s...
متن کاملComparison of osteogenic potential of poly-ether-ether-ketone with titanium-coated poly-ether-ether-ketone and titanium-blended poly-ether-ether-ketone: An in vitro study
STATEMENT OF PROBLEM Poly-ether-ether-ketone (PEEK), a high-performance semi-crystalline thermoplastic polymer, has been employed to replace the metallic implant components in orthopedics. There were various studies performed in accordance to medical grade PEEK, but the relationship between titanium dioxide (TiO2)-coated PEEK, TiO2-blended PEEK, and untreated PEEK still remains complicated, eve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Dental Materials Journal
سال: 2021
ISSN: ['0287-4547', '1881-1361']
DOI: https://doi.org/10.4012/dmj.2019-298