Comparison of Saccadic Vector Optokinetic Perimetry and Standard Automated Perimetry in Glaucoma. Part I: Threshold Values and Repeatability

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Saccadic Vector Optokinetic Perimetry and Standard Automated Perimetry in Glaucoma. Part I: Threshold Values and Repeatability

PURPOSE We evaluated threshold saccadic vector optokinetic perimetry (SVOP) and compared results to standard automated perimetry (SAP). METHODS A cross-sectional study was done including 162 subjects (103 with glaucoma and 59 healthy subjects) recruited at a university hospital. All subjects underwent SAP and threshold SVOP. SVOP uses an eye tracker to monitor eye movement responses to stimul...

متن کامل

Comparison of Threshold Saccadic Vector Optokinetic Perimetry (SVOP) and Standard Automated Perimetry (SAP) in Glaucoma. Part II: Patterns of Visual Field Loss and Acceptability

PURPOSE We compared patterns of visual field loss detected by standard automated perimetry (SAP) to saccadic vector optokinetic perimetry (SVOP) and examined patient perceptions of each test. METHODS A cross-sectional study was done of 58 healthy subjects and 103 with glaucoma who were tested using SAP and two versions of SVOP (v1 and v2). Visual fields from both devices were categorized by m...

متن کامل

Feasibility, Accuracy, and Repeatability of Suprathreshold Saccadic Vector Optokinetic Perimetry

PURPOSE To evaluate feasibility, accuracy, and repeatability of suprathreshold Saccadic Vector Optokinetic Perimetry (SVOP) by comparison with Humphrey Field Analyzer (HFA) perimetry. METHODS The subjects included children with suspected field defects (n = 10, age 5-15 years), adults with field defects (n = 33, age 39-78 years), healthy children (n = 12, age 6-14 years), and healthy adults (n...

متن کامل

Diagnostic Ability and Repeatability of a New Supra-Threshold Glaucoma Screening Program in Standard Automated Perimetry

PURPOSE We assess the diagnostic ability and repeatability of a new suprathreshold glaucoma screening test (GST) comprising 28 test points and a 1-of-3 sampling strategy at 95% of the normal limit for standard automated perimetry (SAP) in early to advanced glaucoma. METHODS This prospective cross-sectional study included 96 eyes of patients with early, moderate, or advanced glaucoma and 37 ey...

متن کامل

Repeatability of automated perimetry: a comparison between standard automated perimetry with stimulus size III and V, matrix, and motion perimetry.

PURPOSE Standard automated perimetry (SAP) shows a marked increase in variability in damaged areas of the visual field. This study was conducted to test the hypothesis that larger stimuli are associated with more uniform variability, by investigating the retest variability of four perimetry tests: standard automated perimetry size III (SAP III), with the SITA standard strategy; SAP size V (SAP ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Translational Vision Science & Technology

سال: 2017

ISSN: 2164-2591

DOI: 10.1167/tvst.6.5.3