Comparison of sequentially measured Aloka echo-tracking one-point pulse wave velocity with SphygmoCor carotid–femoral pulse wave velocity

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of sequentially measured Aloka echo-tracking one-point pulse wave velocity with SphygmoCor carotid-femoral pulse wave velocity.

OBJECTIVES Recently, echo-tracking-derived measures of arterial stiffness have been introduced in clinical practice for the assessment of one-point pulse wave velocity. The purpose of this study was to find a relation between carotid-femoral pulse wave velocity and one-point carotid pulse wave velocity, and to find a value of one-point carotid pulse wave velocity that predicts carotid-femoral p...

متن کامل

Aortic Pulse Wave Velocity Measured by Pulse Wave Imaging (pwi): a Comparison with Applanation Tonometry.

BACKGROUND Arterial stiffness is a well-established indicator of cardiovascular disease outcome. Pulse Wave Velocity (PWV) is a surrogate for arterial stiffness that is measured either globally using carotid to femoral applanation tonometry or locally using biomedical imaging methods. Pulse Wave Imaging (PWI) is an ultrasound-based method for both qualitative visualisation of pulse wave propaga...

متن کامل

Pulse Wave Analysis and Pulse Wave Velocity

momanometer that provides arterial pressures (brachial systolic and diastolic pressure) is coming under question. The concerns extend well beyond the familiar issue of “white coat” hypertension, home and 24-h blood pressure recordings, and the phase-out of mercury based instruments. These concerns relate to the inaccuracy of all cuff devices for measuring pressure within the brachial artery, th...

متن کامل

Pulse-wave velocity measured in one heartbeat using MR tagging.

A noninvasive method for measuring the aortic pulse-wave velocity (PWV) in a single heartbeat is introduced. The method sinusoidally tags a column of blood within the vessel, and rapidly acquires a series of 1D projections of the tags as they move (in practice, 64 projections at 4-ms intervals). From these projections, the relative motion of blood at different positions along the vessel is meas...

متن کامل

Pulse wave velocity measurement

The article deals with the investigation of pulse wave propagation in arteries. A part of work involves also design and realization of devices serving for scanning of pulse wave by reflective photoplethysmography. The work describes a use of microcontroller serving for data flow control, communication and analog signal digitalization using integrated analog to digital converter.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: SAGE Open Medicine

سال: 2013

ISSN: 2050-3121,2050-3121

DOI: 10.1177/2050312113507563