Comparison of the Hounsfield Unit Values Obtained From Cone-Beam Computed Tomography (CBCT) and Multidetector Computed Tomography (MDCT) Images for Different Bone Densities
نویسندگان
چکیده
منابع مشابه
Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans
Purpose This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from conebeam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. Materials and Methods A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and th...
متن کاملCorrelation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)
Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...
متن کاملPrevalence of Idiopathic Osteosclerosis on Cone Beam Computed Tomography Images
Objectives: This study was performed to investigate the prevalence of idiopathic osteosclerosis on cone beam computed tomography (CBCT) images of patients. Methods: In this descriptive, cross-sectional study, 240 CBCT scans of patients (125 women, 115 men) referred to a private oral and maxillofacial radiology clinic in Tehran in 2013 were selected and evaluated. Presence of idiopathic osteosc...
متن کاملComparison of Tissue Density in Hounsfield Units in Computed Tomography and Cone Beam Computed Tomography
OBJECTIVES Bone quality and quantity assessment is one of the most important steps in implant treatment planning. Different methods such as computed tomography (CT) and recently suggested cone beam computed tomography (CBCT) with lower radiation dose and less time and cost are used for bone density assessment. This in vitro study aimed to compare the tissue density values in Hounsfield units (H...
متن کاملcomparison of tissue density in hounsfield units in computed tomography and cone beam computed tomography
objectives: bone quality and quantity assessment is one of the most important steps in implant treatment planning. different methods such as computed tomography (ct) and recently suggested cone beam computed tomography (cbct) with lower radiation dose and less time and cost are used for bone density assessment. this in vitro study aimed to compare the tissue density values in hounsfield units (...