Comparison of Zinc Reduction with Platinum Reduction for Analysis of Deuterium-Enriched Water Samples for the Doubly Labeled Water Technique
نویسندگان
چکیده
منابع مشابه
Comparison of zinc reduction with platinum reduction for analysis of deuterium-enriched water samples for the doubly labeled water technique.
OBJECTIVE Isotope ratio mass spectrometry of hydrogen and oxygen is frequently used to determine total energy expenditure (TEE) using doubly labeled water. Conventionally, hydrogen isotope ratio is determined in hydrogen gas generated from water samples using zinc reduction. We compare this with a new automated platinum method to determine the ratios of hydrogen isotopes in deuterium-enriched w...
متن کاملAdaptation of the doubly labeled water method for subjects consuming isotopically enriched water.
The use of doubly labeled water (DLW) to measure energy expenditure is subject to error if the background abundance of the oxygen and hydrogen isotope tracers changes during the test period. This study evaluated the accuracy and precision of different methods by which such background isotope changes can be corrected, including a modified method that allows prediction of the baseline that would ...
متن کاملthe effect of consciousness raising (c-r) on the reduction of translational errors: a case study
در دوره های آموزش ترجمه استادان بیشتر سعی دارند دانشجویان را با انواع متون آشنا سازند، درحالی که کمتر به خطاهای مکرر آنان در متن ترجمه شده می پردازند. اهمیت تحقیق حاضر مبنی بر ارتکاب مکرر خطاهای ترجمانی حتی بعد از گذراندن دوره های تخصصی ترجمه از سوی دانشجویان است. هدف از آن تاکید بر خطاهای رایج میان دانشجویان مترجمی و کاهش این خطاها با افزایش آگاهی و هوشیاری دانشجویان از بروز آنها است.از آنجا ک...
15 صفحه اولan investigation of the types of text reduction in subtitling: a case study of the persian film gilaneh with english subtitles
چکیده ندارد.
15 صفحه اولThe history and theory of the doubly labeled water technique.
Scientists have been measuring energy expenditure by using gas exchange for the past 200 y. This technique is based on earlier work in the 1660s. Gas exchange in respirometers provides accurate and repeatable measures of resting metabolic rate. However, it is impossible to duplicate in a respirometry chamber the diversity of human behaviors that influence energy expenditure. The doubly labeled ...