Component Alignment in Hip Resurfacing Using Computer Navigation

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imageless computer navigation for placement of the femoral component in resurfacing arthroplasty of the hip.

We have investigated the accuracy of placement of the femoral component using imageless navigation in 100 consecutive Birmingham Hip Resurfacings. Pre-operative templating determined the native neck-shaft angle and planned stem-shaft angle of the implant. The latter were verified post-operatively using digital anteroposterior unilateral radiographs of the hip. The mean neck-shaft angle determin...

متن کامل

Reply to Letter to Editor: Femoral Component Positioning in Hip Resurfacing with and Without Navigation

We acknowledge Dr. Andrea Emilio Salvi for his general comments and opinions on hip resurfacing surgical technique and factors that may affect clinical outcome. Even if no specific question or comment is directly related to our study [2], we will try to provide a scientific input on the points raised. The first ‘‘procedural trap’’ reported by Dr. Salvi is in relation to the femoral component st...

متن کامل

Letter to the Editor: Femoral Component Positioning in Hip Resurfacing with and Without Navigation

UNLABELLED Early failures after hip resurfacing often are the result of technical errors in placing the femoral component. We asked whether image-free computer navigation decreased the number of outliers compared with the conventional nonnavigated technique. We retrospectively compared 51 consecutive hip resurfacings performed using image-free computer navigation with 88 consecutive hip resurfa...

متن کامل

Femoral neck fracture following hip resurfacing: the effect of alignment of the femoral component.

A total of 20 pairs of fresh-frozen cadaver femurs were assigned to four alignment groups consisting of relative varus (10 degrees and 20 degrees) and relative valgus (10 degrees and 20 degrees), 75 composite femurs of two neck geometries were also used. In both the cadaver and the composite femurs, placing the component in 20 degrees of valgus resulted in a significant increase in load to fail...

متن کامل

Alignment Analyses in the Varus Osteoarthritic Knee Using Computer Navigation.

Osteoarthritic (OA) knees with severe extension varus deformity seem to have correspondingly more severe flexion varus, especially beyond a certain tibiofemoral angle. Clinical measurement of flexion varus and fixed flexion deformity (FFD), which had been difficult to perform because of the spatial alignment of the knee in flexion, was recently made possible with computer navigation. We conduct...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Orthopaedics and Related Research

سال: 2008

ISSN: 0009-921X,1528-1132

DOI: 10.1007/s11999-008-0584-x