Compressed sensing fMRI using gradient-recalled echo and EPI sequences
نویسندگان
چکیده
منابع مشابه
Compressed sensing fMRI using gradient-recalled echo and EPI sequences
Compressed sensing (CS) may be useful for accelerating data acquisitions in high-resolution fMRI. However, due to the inherent slow temporal dynamics of the hemodynamic signals and concerns of potential statistical power loss, the CS approach for fMRI (CS-fMRI) has not been extensively investigated. To evaluate the utility of CS in fMRI application, we systematically investigated the properties...
متن کاملComparison of gradient-recalled-echo and T2-weighted spin-echo pulse sequences in intramedullary spinal lesions.
Nineteen consecutive patients with spinal intramedullary lesions were studied on a 1.5-T system to compare the quality of T2-weighted spin-echo and gradient-recalled-echo (GRE) pulse sequences. Direct comparisons were made in the sagittal and/or axial planes. Twenty-four studies were performed in the 19 patients. The gradient echoes were usually performed at 300/14 (TR/TE) with a flip angle of ...
متن کاملCorrection for EPI distortions using multi-echo gradient-echo imaging.
A novel and effective technique is described for distortion correction in echo planar imaging (EPI) utilizing the field maps derived from multi-echo gradient-echo images. The distortions from different off-resonance related factors such as field inhomogeneity, eddy current effect, radiofrequency pulse frequency offset, and chemical shift effect can be simultaneously reduced to a great extent. W...
متن کاملCompressed Sensing for fMRI: Feasibility Study on the Acceleration of Non-EPI fMRI at 9.4T
Conventional functional magnetic resonance imaging (fMRI) technique known as gradient-recalled echo (GRE) echo-planar imaging (EPI) is sensitive to image distortion and degradation caused by local magnetic field inhomogeneity at high magnetic fields. Non-EPI sequences such as spoiled gradient echo and balanced steady-state free precession (bSSFP) have been proposed as an alternative high-resolu...
متن کاملfMRI of the brainstem using dual-echo EPI
The brainstem is the part of the human brain that plays a pivotal role in the maintenance of many critical body functions. Due to the elevated level of cardiogenic noise, few fMRI studies have investigated the brainstem so far. Cardiac-gated echo-planar imaging with acquisition of two echoes per excitation (dual-echo EPI) is one method that significantly reduces cardiogenic noise and, thus, all...