Compromised Vibration Isolator of Electric Power Generator Considering Self-Excitation and Basement Input

نویسندگان

چکیده

A previous study proposed an optimal vibration isolator for self-excitation, but the solution results showed a critical drawback basement input. Because plant system is exposed to self-excitation and input, characteristics must meet all requirements of both excitation cases. Two performance indices were introduced evaluate control capability over two cases, using theoretical linear model electric power generator. The compromise strategy was devoted enhancing owing acceptable margin self-excitation. modification mechanical properties focused on between mass block surrounding building. Simulation revealed that increase in spring coefficient decrease damping beneath could enhance reduction

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Loss of Excitation Detection in Doubly Fed Induction Generator by Voltage and Reactive Power Rate

The doubly fed induction generator (DFIG) is one of the most popular technologies used in wind power systems. With the growing use of DFIGs and increasing power system dependence on them in recent years, protecting of these generators against internal faults is more considered. Loss of excitation (LOE) event is among the most frequent failures in electric generators. However, LOE detection stud...

متن کامل

loss of excitation detection in doubly fed induction generator by voltage and reactive power rate

the doubly fed induction generator (dfig) is one of the most popular technologies used in wind power systems. with the growing use of dfigs and increasing power system dependence on them in recent years, protecting of these generators against internal faults is more considered. loss of excitation (loe) event is among the most frequent failures in electric generators. however, loe detection stud...

متن کامل

Capacitance requirement for isolated self-excited induction generator - Electric Power Applications [see also IEE Proceedings-Electric Power Applications], IEE Proceeding

Abstract: Advanced knowledge of the minimum capacitor value required for self-excitation of an induction generator is of practical interest. To find this capacitor value two nonlinear equations have to be solved. Different numerical methods for solving these equations are known from previous literature. However, these solutions involve some guessing in a trial-and-error procedure. In the paper ...

متن کامل

a study of relationship between knowledge sharing and organizational agility among personnel in esfahan power electric distribution company

پژوهش حاضر به بررسی رابطه بین تسهیم دانش و چابکی سازمانی در شرکت توزیع برق استان اصفهان پرداخته است . ابزار سنجش در این پژوهش پرسشنامه می باشد . به منظور سنجش متغیر تسهیم دانش از پرسشنامه وانگ و وانگ و جهت سنجش چابکی سازمانی از پرسشنامه چاربونیر استفاده شده است . هدف پژوهش حاضر تحلیل رابطه میان تسهیم دانش و چابکی سازمانی از دید کارکنان شرکت توزیع برق استان اصفهان می باشد . جامعه آماری این پژوه...

15 صفحه اول

Investigation of STATCOM effects on synchronous generator impedance based LOF relay with considering a realistic model for the excitation system of the generator

This paper studies the effects of static synchronous compensator (STATCOM) on synchronous generator conventional loss of field (LOF) protection. To accomplish a comprehensive study, a typical and realistic excitation system is considered for the generator by using the phase-domain generator model available in the real-time-digital-simulator. Using such a system, LOF phenomenon is realistically ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Inventions

سال: 2023

ISSN: ['2411-5134']

DOI: https://doi.org/10.3390/inventions8010040