Computational adaptive optics for broadband optical interferometric tomography of biological tissue.

Aberrations in optical microscopy reduce image resolution and contrast, and can limit imaging depth when focusing into biological samples. Static correction of aberrations may be achieved through appropriate lens design, but this approach does not offer the flexibility of simultaneously correcting aberrations for all imaging depths, nor the adaptability to correct for sample-specific aberration...

متن کامل

Guide-star-based computational adaptive optics for broadband interferometric tomography.

We present a method for the numerical correction of optical aberrations based on indirect sensing of the scattered wavefront from point-like scatterers ("guide stars") within a three-dimensional broadband interferometric tomogram. This method enables the correction of high-order monochromatic and chromatic aberrations utilizing guide stars that are revealed after numerical compensation of defoc...

متن کامل

Automated interferometric synthetic aperture microscopy and computational adaptive optics for improved optical coherence tomography.

In this paper, we introduce an algorithm framework for the automation of interferometric synthetic aperture microscopy (ISAM). Under this framework, common processing steps such as dispersion correction, Fourier domain resampling, and computational adaptive optics aberration correction are carried out as metrics-assisted parameter search problems. We further present the results of this algorith...

متن کامل

Computational adaptive optics for live three-dimensional biological imaging.

Light microscopy of thick biological samples, such as tissues, is often limited by aberrations caused by refractive index variations within the sample itself. This problem is particularly severe for live imaging, a field of great current excitement due to the development of inherently fluorescent proteins. We describe a method of removing such aberrations computationally by mapping the refracti...