Condition Evaluation of Large Generator Stator Insulation Based on Partial Discharge Measurement

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Partial discharge database: its benefits and limitations on assessment of stator insulation deterioration

PD test data on various generators and motors has been collected over the last 15 years using on-line partial discharge analyzers. A large PD test database has been established. The database provides an overall view of PD activity on rotating machines. Statistical analysis of the database provides a study of PD distribution with variations of a number of the parameters. This paper presents stat...

متن کامل

Study of Aging Characteristics of Generator Stator Insulation Based on Temperature Spectrum of Dielectric Dissipation Factor

In this paper, accelerated multi-factor aging tests in laboratory have been conducted on the stator ham of a large generator. During the period of aging, the temperature spectra of dielectric dissipation factor tan 6 of stator insulation were employed to investigate aging characteristics of insulation materials. Test results showed that the peak temperature T,,, of the tan 6 -T curve under 0.2U...

متن کامل

Improvement of Stator Slot Structure based on Insulation Stresses Analysis in HV Generator

High voltage generators are being subject to higher voltage rating and are being designed to operate in harsh conditions. Stator windings are the main component of generators in which Electrical, magnetical and thermal stresses remain major failures for insulation degradation accelerated aging. A large number of generators failed due to stator winding problems, mainly insulation deterioration. ...

متن کامل

Comparison and Analysis of On-line Partial Discharge Measurement Methods for Gas Insulation Substation

In this paper, we compare and analyze the signals of acoustic emission (AE) sensor, high-frequency current transformer (HF-CT) and capacitive coupled (CC) sensor inspection methods when they are used to detect the partial discharge (PD) in gas isolation substations (GIS). The PD location feasibility of the AE method is also studied. In general, the leakage currents are measured by using the HF-...

متن کامل

Nusselt Number Measurement of Air Flow between Grooved Rotor and Stator of a Generator

In this article, turbulent flow heat transfer in the air gap between rotor and stator of a generator under nonhomogeneous heat flux is studied experimentally. The rotor consists of four symmetrical triangular grooves. The stator surface is smooth and does not include any grooves. The relative heat flux between the rotor and the stator is 1 to 3. Temperature and heat flux are measured locally at...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Advances in Mechanical Engineering

سال: 2013

ISSN: 1687-8140,1687-8140

DOI: 10.1155/2013/765374