Conducting Polymer?Ionic Liquid Electrode Arrays for High?Density Surface Electromyography

نویسندگان

چکیده

Surface electromyography (EMG) is used as a medical diagnostic and to control prosthetic limbs. Electrode arrays that provide large-area, high density recordings have the potential yield significant improvements in both fronts, but need remains largely unfulfilled. Here, digital fabrication techniques are make scalable electrode capture EMG signals with mm spatial resolution. Using electrodes made of poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) composites biocompatible ionic liquid (IL) cholinium lactate, enable quality spatiotemporal from forearm volunteers. These allow identify motions index, little, middle fingers, directly visualize propagation polarization/depolarization waves underlying muscles. This work paves way for cutaneous electrophysiology personalized medicine highly articulate prostheses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Review of surface electrode placement for recording electromyography signals

Background: Surface Electromyography (SEMG) signal has used in monitoring muscle activities. It has been widely applied in many areas, such as body member prosthesis, noise cancellation for braincomputer interface, and robotics. The SEMG acquisition method for collecting the signal with low-noise has extensively investigated in the last decade. The objective of this study is to review the recen...

متن کامل

Electrode Placement in Surface Electromyography (sEMG) “Minimal Crosstalk Area” (MCA)

This paper is an introduction to a workshop on electrodes location and specific exercises. Selectivity of EMG electrodes depends on their interspacing, their conductive area and axis direction with respect to the direction of the underlying muscular fibres. Minimal cross talk area (MCA) helps to limit or avoid crosstalk from neighbouring muscles. We present examples of MCA and typical sEMG patt...

متن کامل

Tensor veli palatini electromyography with surface electrode applied transnasally.

A new technique is proposed for paratubal electromyography, using a surface, non-invasive, electrode applied transnasally under nasopharyngoscope guidance. This electrode records activity of the tensor veli palatini muscle during swallowing. This technique is of interest for two reasons: endoscopic guidance offers the possibility to check correct positioning of the electrode recording at tensor...

متن کامل

Conducting polymer-hydrogels for medical electrode applications.

Conducting polymers hold significant promise as electrode coatings; however, they are characterized by inherently poor mechanical properties. Blending or producing layered conducting polymers with other polymer forms, such as hydrogels, has been proposed as an approach to improving these properties. There are many challenges to producing hybrid polymers incorporating conducting polymers and hyd...

متن کامل

Improved thin-layer electrolysis cell for ion transfer at the liquid|liquid interface using a conducting polymer-coated electrode.

This article reviews the development of a thin-layer electrolysis cell with both a thin aqueous phase and a thin organic phase for ion transfer at the liquid|liquid interface for the absolute determination of a redox-inactive ion. In particular, an improvement of the cell performance by using a conducting polymer-coated electrode in the organic phase is discussed. The applicability of the thin-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Advanced Healthcare Materials

سال: 2021

ISSN: ['2192-2640', '2192-2659']

DOI: https://doi.org/10.1002/adhm.202100374