Conjoint Removal of Hip Screw-Femur Head during Hip Replacement after Previous Dynamic Hip Screw Fixation

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic hip screw blade fixation for intertrochanteric hip fractures.

PURPOSE To assess the one-year outcome of a dynamic hip screw (DHS) blade in the treatment of AO/OTA 31-A1 and 31-A2 intertrochanteric hip fractures. METHODS 35 men and 65 women aged 47 to 100 (mean, 83) years underwent fixation with a DHS blade for A1 (n=47) and A2 (n=53) intertrochanteric hip fractures after a low-energy injury. Patients were operated on within 48 hours of admission. Antero...

متن کامل

Total hip arthroplasty following failure of dynamic hip screw fixation of fractures of the proximal femur.

Thirty-two patients (11 male, 21 female) with a mean age of 64 years were prospectively studied after undergoing total hip replacement after failed treatment of intertrochanteric fractures. One patient had bilateral surgery. The mean time from primary surgery to the salvage arthroplasty was 15 months (range, 4 to 32 months). The mean follow-up period was 57 months (range, 30 to 108 months). Int...

متن کامل

Comparison of Intertrochanteric Fracture Fixation with Dynamic Hip Screw and Bipolar Hemiarthroplasty Techniques

Background: At present, there is no consensus on an appropriate treatment modality for intertrochanteric fractures in the elderly with background diseases. The aim of the present study was to compare treatment outcomes of intertrochanteric fractures reduced with dynamic hip screws (DHS) and bipolar hemiarthroplasty in elderly patients with background medical conditions. Methods: In this randomi...

متن کامل

Ipsilateral Intracapsular Hip Fracture 2 Years after Fixation of Extracapsular Fracture by Dynamic Hip Screw

INTRODUCTION Sustaining an intracapsular fracture in a hip which was previously fixed with dynamic hip screw for extracapsular fracture, is a very rarely reported occurrence. We present one such case in order to discuss the presentation and management of this fracture. We have also reviewed the literature and pooled the previously reported cases to look at potential cause & risk factors. CASE...

متن کامل

Salvage of failed dynamic hip screw fixation of intertrochanteric fractures.

Twenty-six patients with failed dynamic hip screw fixation of intertrochanteric fractures were included in this study. The mean age of the patients was 61 years (range, 38-84 years). Average limb shortening was 2.4 cm; 18 patients were treated with revision internal fixation and eight patients with prosthetic replacement. The decision depended on the physiological age of the patient, quality of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Orthopaedic Surgery

سال: 2018

ISSN: 1757-7853

DOI: 10.1111/os.12403