Consideration from Viewpoint of Output Impedance Concerning Control Method for Parallel Operation of CVCF Inverters

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Load Sharing Control of Parallel Inverters with Uncertainty in the Output Filter Impedances for Islanding Operation of AC Micro-Grid

Parallel connection of inverter modules is a solution to increase reliability, efficiency and redundancy of inverters in Micro-Grid system. Proper load sharing among parallel inverters is a key point. The circulating current among the inverters can greatly reduce the efficiency or even cause instability of the system. In this paper, a control strategy for improving the load sharing performance ...

متن کامل

Droop Control of Parallel Inverters with LCL Filter and Virtual Output Impedance

Because of the acute shortage of conventional energy resources, renewable energy harness is gaining attention. Voltage source inverter forms the interface to feed the power from the renewable source to utility. In order to increase the modularity of the system, the use of several parallel inverters of reduced rating is preferred. An effective control strategy to maintain the amplitude and frequ...

متن کامل

Simplified control method for parallel-connected DC/AC inverters

The parallel operation of several low-capacity inverters is better than a singular highcapacity inverter owing to the advantages of better extensibility and reliability. A simplified control method for parallel-connected inverters is proposed, which can balance the current distribution among the parallel-connected inverters with no interconnected communication lines. To verify the performance o...

متن کامل

Bounded droop controller for parallel operation of inverters

In this paper, the stability of parallel-operated inverters in the sense of boundedness is investigated. At first, the non-linear model of parallelled inverters with a generic linear or non-linear load is obtained by using the generalised dissipative Hamiltonian structure and then the robust droop controller, recently proposed in the literature for parallel operation of inverters, is implemente...

متن کامل

Implementation of Control Variables to Exploit Output Power for SRGs in Single Pulse Mode Operation

This paper presents an analytical modeling method of optimal control variables to maximize output power for switched reluctance generators (SRGs) in single pulse mode operation. This method extends the basic theory of the Stiebler model and utilizes the flux linkage function to express the inductance model of SRG. In this paper, the optimal phase current shape of SRG for maximum output power is...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEJ Transactions on Industry Applications

سال: 2008

ISSN: 0913-6339,1348-8163

DOI: 10.1541/ieejias.128.102