Consideration of Radiometric Quantization Error in Satellite Sensor Cross-Calibration
نویسندگان
چکیده
منابع مشابه
Imager-to-radiometer in-flight cross calibration: RSP radiometric comparison with airborne and satellite sensors
This work develops a method to compare the radiometric calibration between a radiometer and imagers hosted on aircraft and satellites. The radiometer is the airborne Research Scanning Polarimeter (RSP), which takes multi-angle, photo-polarimetric measurements in several spectral channels. The RSP measurements used in this work were coincident with measurements made by the Airborne Visible/Infra...
متن کاملRADIOMETRIC CAMERA CALIBRATION OF THE BiLSAT SMALL SATELLITE: PRELIMINARY RESULTS
The studies on radiometric camera calibration of multispectral camera of the BiLSAT satellite is presented in this work. During the study, various dark images and flat-field images have been taken, and deviations from ideal has been investigated. Various sources of error have been studied and the non-homogeneous response of the CCD is explicitly modeled. Images have been corrected according to ...
متن کاملRadiometric Cross-Calibration of GF-4 PMS Sensor Based on Assimilation of Landsat-8 OLI Images
Earth observation data obtained from remote sensors must undergo radiometric calibration before use in quantitative applications. However, the large view angles of the panchromatic multispectral sensor (PMS) aboard the GF-4 satellite pose challenges for cross-calibration due to the effects of atmospheric radiation transfer and the bidirectional reflectance distribution function (BRDF). To addre...
متن کاملRadiometric Cross-Calibration of GF-4 in Multispectral Bands
The GaoFen-4 (GF-4), launched at the end of December 2015, is China’s first high-resolution geostationary optical satellite. A panchromatic and multispectral sensor (PMS) is onboard the GF-4 satellite. Unfortunately, the GF-4 has no onboard calibration assembly, so on-orbit radiometric calibration is required. Like the charge-coupled device (CCD) onboard HuanJing-1 (HJ) or the wide field of vie...
متن کاملRadiometric inter-sensor cross-calibration uncertainty using a traceable high accuracy reference hyperspectral imager
Optical earth observation (EO) satellite sensors generally suffer from drifts and biases relative to their pre-launch calibration, caused by launch and/or time in the space environment. This places a severe limitation on the fundamental reliability and accuracy that can be assigned to satellite derived information, and is particularly critical for long time base studies for climate change and e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Remote Sensing
سال: 2018
ISSN: 2072-4292
DOI: 10.3390/rs10071131